Welcome
Welcome
Lenovo Product Portfolio
Welcome
Lenovo Product Portfolio
ThinkSystem compute nodes
ThinkSystem SN550 Type 7X16
Resources and downloads
Compute node package contents
Features
Specifications
Particulate contamination
Management offerings
Compute node components
Front view
Compute node controls, connectors, and LEDs
System-board layout
System-board connectors
System-board switches
KVM cable
Parts list
Compute node hardware setup
Compute node setup checklist
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Install compute node hardware options
Remove the top cover
Remove the air baffle
Remove the 2.5-inch drive backplane
Remove the RAID adapter
Install a 2.5-inch drive backplane
Install a 2.5-inch hot-swap drive
Install a DIMM
DIMM configuration
DIMM Installation order
DC Persistent Memory Module (DCPMM) setup
DC Persistent Memory Module (DCPMM) installation order
Install the flash power module
Install an I/O expansion adapter
Install the M.2 backplane
Install an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install a processor-heat-sink module
Install a RAID adapter
Install the air baffle
Install the compute node cover
Install the compute node in the chassis
Power on the compute node
Validate compute node setup
Power off the compute node
System configuration
Set the network connection for the
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
DIMM configuration
Independent memory mode
Memory mirroring mode
Memory rank sparing mode
DC Persistent Memory Module - Memory Mode
RAID configuration
Deploy the operating system
Back up the compute node configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Hardware replacement procedures
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Returning a device or component
Updating the compute node configuration
Compute node replacement
Remove the compute node from the chassis
Install the compute node in the chassis
2.5-inch hot-swap drive replacement
Remove a 2.5-inch hot-swap drive
Install a 2.5-inch hot-swap drive
2.5-inch drive backplane replacement
Remove the 2.5-inch drive backplane
Install a 2.5-inch drive backplane
Air baffle replacement
Remove the air baffle
Install the air baffle
Adapter-retention assembly replacement
Remove the adapter-retention assembly
Install the adapter-retention assembly
Bezel replacement
Remove the bezel
Install the bezel
Chassis bulkhead replacement
Remove the bulkhead
Install the bulkhead
CMOS battery - CR2032 replacement
Remove the CMOS battery - CR2032
Install the CMOS battery - CR2032
Compute node cover replacement
Remove the compute node cover
Install the compute node cover
DIMM replacement
Remove a DIMM
Install a DIMM
Fabric connector replacement
Remove a fabric connector
Install a fabric connector
Flash power module replacement
Remove the flash power module
Install the flash power module
Front handle replacement
Remove the front handle
Install the front handle
ID label plate replacement
Remove the ID label plate
Install the ID label plate
I/O expansion adapter replacement
Remove an I/O expansion adapter
Install an I/O expansion adapter
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement
Remove an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install an M.2 drive
Processor and heat sink replacement
Remove a processor and heat sink
Install a processor and heat sink
RFID tag replacement
Remove the RFID tag
Install the RFID tag
RAID adapter replacement
Remove a RAID adapter
Install a RAID adapter
Storage cage replacement
Remove the storage cage
Install the storage cage
System-board assembly replacement
Remove and replace the system-board assembly
Update the machine type and serial number
Enable TPM/TCM
Set the TPM/TCM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
TCM/TPM adapter replacement (for Chinese Mainland only)
Remove the TCM/TPM adapter (for Chinese Mainland only)
Install the TCM/TPM adapter (for Chinese Mainland only)
Problem determination
Event logs
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
System-board LEDs
General problem determination procedures
Troubleshooting by symptom
Hard disk drive problems
Intermittent problems
Memory problems
Network problems
Access problems
Communication problems
Connectivity problems
Ping problems
Observable problems
Optional-device problems
Performance problems
Power on and power off problems
Software problems
Messages
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0004N
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDA0000N
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW0000N
FQXSPFW0001N
FQXSPFW0002N
FQXSPFW2000I
FQXSPFW2001I
FQXSPFW2002I
FQXSPIO0001L
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0011N
FQXSPIO0013N
FQXSPIO0014J
FQXSPIO0015M
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPIO2011I
FQXSPIO2013I
FQXSPIO2015I
FQXSPMA0002N
FQXSPMA0004I
FQXSPMA0005N
FQXSPMA0006N
FQXSPMA0007L
FQXSPMA0008N
FQXSPMA0010J
FQXSPMA0011G
FQXSPMA0012M
FQXSPMA0013N
FQXSPMA0015L
FQXSPMA0017J
FQXSPMA0019M
FQXSPMA2002I
FQXSPMA2004I
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2008I
FQXSPMA2010I
FQXSPMA2011I
FQXSPMA2012I
FQXSPMA2013I
FQXSPMA2015I
FQXSPMA2017I
FQXSPMA2019I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0001I
FQXSPPR0002I
FQXSPPR2000I
FQXSPPR2002I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU0004M
FQXSPPU0008I
FQXSPPU0009N
FQXSPPU0011N
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2003I
FQXSPPU2004I
FQXSPPU2008I
FQXSPPU2009I
FQXSPPU2010G
FQXSPPU2011I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0016K
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0063M
FQXSPPW2008I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPSB0000N
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0009I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0024I
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2009I
FQXSPUN2010I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2026I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
Lenovo XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
Tech Tips
Security advisories
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem SN850 Type 7X15
Resources and downloads
Compute node package contents
Features
Specifications
Particulate contamination
Management offerings
Compute node components
Front view
Compute node controls, connectors, and LEDs
System-board layout
System-board connectors
System-board switches
KVM cable
Parts list
Compute node hardware setup
Compute node setup checklist
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the compute node with the power on
Handling static-sensitive devices
Install compute node hardware options
Remove the compute node cover
Remove the air baffle
Install a 2.5-inch drive backplane
Install a 2.5-inch hot-swap drive
Install a DIMM
DC Persistent Memory Module (DCPMM) setup
DC Persistent Memory Module (DCPMM) installation order
Memory guidelines
Memory module installation order
Independent memory mode
Installation order: independent memory mode with two processors
Installation order: independent memory mode with four processors
Memory mirroring
Installation order: memory mirroring with two processors
Installation order: memory mirroring with four processors
Memory sparing
Installation order: memory sparing with two processors
Installation order: memory sparing with four processors
DC Persistent Memory Module — Memory Mode
Installation order: Memory Mode with two processors
Installation order: Memory Mode with four processors
Install an I/O expansion adapter
Install an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install the M.2 backplane
Install a processor-heat-sink module
Install the interposer card
Install a RAID adapter
Install the flash power module
Remove the 2.5-inch drive backplane
Remove the RAID adapter
Install the air baffle
Install the compute node cover
Install a compute node
Power on the compute node
Validate compute node setup
Power off the compute node
System configuration
Set the network connection for the
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
RAID configuration
Deploy the operating system
Back up the server configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Hardware replacement procedures
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the server with the power on
Power off the compute node
Handling static-sensitive devices
2.5-inch drive backplane replacement
Remove a 2.5-inch drive backplane
Install a 2.5-inch drive backplane
2.5-inch hot-swap drive replacement
Remove a 2.5-inch hot-swap drive
Install a 2.5-inch hot-swap drive
Adapter-retention assembly replacement
Remove the adapter-retention assembly
Install the adapter-retention assembly
Air baffle replacement
Remove the air baffle
Install the air baffle
Bezel replacement
Remove the bezel
Install the bezel
Bulkhead replacement
Remove the bulkhead
Install the bulkhead
CMOS battery replacement
Remove the CMOS battery
Install the CMOS battery - CR2032
Compute node replacement
Remove a compute node
Install a compute node
Compute node cover replacement
Remove the compute node cover
Install the compute node cover
DIMM replacement
Remove a DIMM
Install a DIMM
Fabric connector replacement
Remove a fabric connector
Install a fabric connector
Flash power module replacement
Remove the flash power module
Install the flash power module
Front handle replacement
Remove the front handle
Install the front handle
ID label plate replacement
Remove the ID label plate
Install the ID label plate
Interposer card replacement
Remove the interposer card
Install the interposer card
I/O expansion adapter replacement
Remove an I/O expansion adapter
Install an I/O expansion adapter
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement
Remove an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install an M.2 drive
Processor and heat sink replacement
Remove a processor and heat sink
Install a processor and heat sink
RAID adapter replacement
Remove the RAID adapter
Install the RAID adapter
RFID tag replacement
Remove the RFID tag
Install the RFID tag
Storage cage replacement
Remove a storage cage
Install a storage cage
System-board assembly replacement
Remove and replace the system-board assembly
Update the machine type and serial number
Enable TPM/TCM
Set the TPM/TCM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
TCM/TPM adapter replacement (for China only)
Remove the TCM/TPM adapter (for China only)
Install the TCM/TPM adapter (for China only)
Complete the parts replacement
Problem determination
Event logs
Light path diagnostics
System-board LEDs
General problem determination procedures
Troubleshooting by symptom
Hard disk drive problems
Intermittent problems
Memory problems
Network problems
Access problems
Communication problems
Connectivity problems
Ping problems
Observable problems
Optional-device problems
Performance problems
Power on and power off problems
Software problems
Messages
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA0021I
FQXSPCA0025N
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCA2025I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW0000N
FQXSPFW0001N
FQXSPFW0002N
FQXSPFW2000I
FQXSPFW2001I
FQXSPFW2002I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0010I
FQXSPIO0011N
FQXSPIO0013N
FQXSPIO0015M
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPIO2011I
FQXSPIO2013I
FQXSPIO2015I
FQXSPMA0002N
FQXSPMA0004I
FQXSPMA0005N
FQXSPMA0006N
FQXSPMA0007L
FQXSPMA0008N
FQXSPMA0010J
FQXSPMA0011G
FQXSPMA0012M
FQXSPMA0013N
FQXSPMA0015L
FQXSPMA0017J
FQXSPMA0019M
FQXSPMA2002I
FQXSPMA2004I
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2008I
FQXSPMA2010I
FQXSPMA2011I
FQXSPMA2013I
FQXSPMA2015I
FQXSPMA2017I
FQXSPMA2019I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0001I
FQXSPPR0002I
FQXSPPR2000I
FQXSPPR2002I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU0004M
FQXSPPU0008I
FQXSPPU0009N
FQXSPPU0011N
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2003I
FQXSPPU2004I
FQXSPPU2008I
FQXSPPU2009I
FQXSPPU2010G
FQXSPPU2011I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0063M
FQXSPPW2008I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0009I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0024I
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2009I
FQXSPUN2010I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2026I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI error messages
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
Lenovo XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
Tech Tips
Security advisories
Hardware disassembling for recycle
Disassemble the system-board assembly for recycle
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem SN550 Type 7X16
Resources and downloads
Compute node package contents
Features
Specifications
Particulate contamination
Management offerings
Compute node components
Front view
Compute node controls, connectors, and LEDs
System-board layout
System-board connectors
System-board switches
KVM cable
Parts list
Compute node hardware setup
Compute node setup checklist
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Install compute node hardware options
Remove the top cover
Remove the air baffle
Remove the 2.5-inch drive backplane
Remove the RAID adapter
Install a 2.5-inch drive backplane
Install a 2.5-inch hot-swap drive
Install a DIMM
DIMM configuration
DIMM Installation order
DC Persistent Memory Module (DCPMM) setup
DC Persistent Memory Module (DCPMM) installation order
Install the flash power module
Install an I/O expansion adapter
Install the M.2 backplane
Install an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install a processor-heat-sink module
Install a RAID adapter
Install the air baffle
Install the compute node cover
Install the compute node in the chassis
Power on the compute node
Validate compute node setup
Power off the compute node
System configuration
Set the network connection for the
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
DIMM configuration
Independent memory mode
Memory mirroring mode
Memory rank sparing mode
DC Persistent Memory Module - Memory Mode
RAID configuration
Deploy the operating system
Back up the compute node configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Hardware replacement procedures
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Returning a device or component
Updating the compute node configuration
Compute node replacement
Remove the compute node from the chassis
Install the compute node in the chassis
2.5-inch hot-swap drive replacement
Remove a 2.5-inch hot-swap drive
Install a 2.5-inch hot-swap drive
2.5-inch drive backplane replacement
Remove the 2.5-inch drive backplane
Install a 2.5-inch drive backplane
Air baffle replacement
Remove the air baffle
Install the air baffle
Adapter-retention assembly replacement
Remove the adapter-retention assembly
Install the adapter-retention assembly
Bezel replacement
Remove the bezel
Install the bezel
Chassis bulkhead replacement
Remove the bulkhead
Install the bulkhead
CMOS battery - CR2032 replacement
Remove the CMOS battery - CR2032
Install the CMOS battery - CR2032
Compute node cover replacement
Remove the compute node cover
Install the compute node cover
DIMM replacement
Remove a DIMM
Install a DIMM
Fabric connector replacement
Remove a fabric connector
Install a fabric connector
Flash power module replacement
Remove the flash power module
Install the flash power module
Front handle replacement
Remove the front handle
Install the front handle
ID label plate replacement
Remove the ID label plate
Install the ID label plate
I/O expansion adapter replacement
Remove an I/O expansion adapter
Install an I/O expansion adapter
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement
Remove an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install an M.2 drive
Processor and heat sink replacement
Remove a processor and heat sink
Install a processor and heat sink
RFID tag replacement
Remove the RFID tag
Install the RFID tag
RAID adapter replacement
Remove a RAID adapter
Install a RAID adapter
Storage cage replacement
Remove the storage cage
Install the storage cage
System-board assembly replacement
Remove and replace the system-board assembly
Update the machine type and serial number
Enable TPM/TCM
Set the TPM/TCM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
TCM/TPM adapter replacement (for Chinese Mainland only)
Remove the TCM/TPM adapter (for Chinese Mainland only)
Install the TCM/TPM adapter (for Chinese Mainland only)
Problem determination
Event logs
Light path diagnostics
Viewing the light path diagnostics LEDs
Light path diagnostics LEDs
System-board LEDs
General problem determination procedures
Troubleshooting by symptom
Hard disk drive problems
Intermittent problems
Memory problems
Network problems
Access problems
Communication problems
Connectivity problems
Ping problems
Observable problems
Optional-device problems
Performance problems
Power on and power off problems
Software problems
Messages
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0004N
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDA0000N
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW0000N
FQXSPFW0001N
FQXSPFW0002N
FQXSPFW2000I
FQXSPFW2001I
FQXSPFW2002I
FQXSPIO0001L
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0011N
FQXSPIO0013N
FQXSPIO0014J
FQXSPIO0015M
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPIO2011I
FQXSPIO2013I
FQXSPIO2015I
FQXSPMA0002N
FQXSPMA0004I
FQXSPMA0005N
FQXSPMA0006N
FQXSPMA0007L
FQXSPMA0008N
FQXSPMA0010J
FQXSPMA0011G
FQXSPMA0012M
FQXSPMA0013N
FQXSPMA0015L
FQXSPMA0017J
FQXSPMA0019M
FQXSPMA2002I
FQXSPMA2004I
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2008I
FQXSPMA2010I
FQXSPMA2011I
FQXSPMA2012I
FQXSPMA2013I
FQXSPMA2015I
FQXSPMA2017I
FQXSPMA2019I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0001I
FQXSPPR0002I
FQXSPPR2000I
FQXSPPR2002I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU0004M
FQXSPPU0008I
FQXSPPU0009N
FQXSPPU0011N
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2003I
FQXSPPU2004I
FQXSPPU2008I
FQXSPPU2009I
FQXSPPU2010G
FQXSPPU2011I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0016K
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0063M
FQXSPPW2008I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPSB0000N
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0009I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0024I
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2009I
FQXSPUN2010I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2026I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
Lenovo XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
Tech Tips
Security advisories
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem SN850 Type 7X15
Resources and downloads
Compute node package contents
Features
Specifications
Particulate contamination
Management offerings
Compute node components
Front view
Compute node controls, connectors, and LEDs
System-board layout
System-board connectors
System-board switches
KVM cable
Parts list
Compute node hardware setup
Compute node setup checklist
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the compute node with the power on
Handling static-sensitive devices
Install compute node hardware options
Remove the compute node cover
Remove the air baffle
Install a 2.5-inch drive backplane
Install a 2.5-inch hot-swap drive
Install a DIMM
DC Persistent Memory Module (DCPMM) setup
DC Persistent Memory Module (DCPMM) installation order
Memory guidelines
Memory module installation order
Independent memory mode
Installation order: independent memory mode with two processors
Installation order: independent memory mode with four processors
Memory mirroring
Installation order: memory mirroring with two processors
Installation order: memory mirroring with four processors
Memory sparing
Installation order: memory sparing with two processors
Installation order: memory sparing with four processors
DC Persistent Memory Module — Memory Mode
Installation order: Memory Mode with two processors
Installation order: Memory Mode with four processors
Install an I/O expansion adapter
Install an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install the M.2 backplane
Install a processor-heat-sink module
Install the interposer card
Install a RAID adapter
Install the flash power module
Remove the 2.5-inch drive backplane
Remove the RAID adapter
Install the air baffle
Install the compute node cover
Install a compute node
Power on the compute node
Validate compute node setup
Power off the compute node
System configuration
Set the network connection for the
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
RAID configuration
Deploy the operating system
Back up the server configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Hardware replacement procedures
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the server with the power on
Power off the compute node
Handling static-sensitive devices
2.5-inch drive backplane replacement
Remove a 2.5-inch drive backplane
Install a 2.5-inch drive backplane
2.5-inch hot-swap drive replacement
Remove a 2.5-inch hot-swap drive
Install a 2.5-inch hot-swap drive
Adapter-retention assembly replacement
Remove the adapter-retention assembly
Install the adapter-retention assembly
Air baffle replacement
Remove the air baffle
Install the air baffle
Bezel replacement
Remove the bezel
Install the bezel
Bulkhead replacement
Remove the bulkhead
Install the bulkhead
CMOS battery replacement
Remove the CMOS battery
Install the CMOS battery - CR2032
Compute node replacement
Remove a compute node
Install a compute node
Compute node cover replacement
Remove the compute node cover
Install the compute node cover
DIMM replacement
Remove a DIMM
Install a DIMM
Fabric connector replacement
Remove a fabric connector
Install a fabric connector
Flash power module replacement
Remove the flash power module
Install the flash power module
Front handle replacement
Remove the front handle
Install the front handle
ID label plate replacement
Remove the ID label plate
Install the ID label plate
Interposer card replacement
Remove the interposer card
Install the interposer card
I/O expansion adapter replacement
Remove an I/O expansion adapter
Install an I/O expansion adapter
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement
Remove an M.2 drive
Adjust the position of the retainer on the M.2 backplane
Install an M.2 drive
Processor and heat sink replacement
Remove a processor and heat sink
Install a processor and heat sink
RAID adapter replacement
Remove the RAID adapter
Install the RAID adapter
RFID tag replacement
Remove the RFID tag
Install the RFID tag
Storage cage replacement
Remove a storage cage
Install a storage cage
System-board assembly replacement
Remove and replace the system-board assembly
Update the machine type and serial number
Enable TPM/TCM
Set the TPM/TCM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
TCM/TPM adapter replacement (for China only)
Remove the TCM/TPM adapter (for China only)
Install the TCM/TPM adapter (for China only)
Complete the parts replacement
Problem determination
Event logs
Light path diagnostics
System-board LEDs
General problem determination procedures
Troubleshooting by symptom
Hard disk drive problems
Intermittent problems
Memory problems
Network problems
Access problems
Communication problems
Connectivity problems
Ping problems
Observable problems
Optional-device problems
Performance problems
Power on and power off problems
Software problems
Messages
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA0021I
FQXSPCA0025N
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCA2025I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW0000N
FQXSPFW0001N
FQXSPFW0002N
FQXSPFW2000I
FQXSPFW2001I
FQXSPFW2002I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0010I
FQXSPIO0011N
FQXSPIO0013N
FQXSPIO0015M
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPIO2011I
FQXSPIO2013I
FQXSPIO2015I
FQXSPMA0002N
FQXSPMA0004I
FQXSPMA0005N
FQXSPMA0006N
FQXSPMA0007L
FQXSPMA0008N
FQXSPMA0010J
FQXSPMA0011G
FQXSPMA0012M
FQXSPMA0013N
FQXSPMA0015L
FQXSPMA0017J
FQXSPMA0019M
FQXSPMA2002I
FQXSPMA2004I
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2008I
FQXSPMA2010I
FQXSPMA2011I
FQXSPMA2013I
FQXSPMA2015I
FQXSPMA2017I
FQXSPMA2019I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0001I
FQXSPPR0002I
FQXSPPR2000I
FQXSPPR2002I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU0004M
FQXSPPU0008I
FQXSPPU0009N
FQXSPPU0011N
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2003I
FQXSPPU2004I
FQXSPPU2008I
FQXSPPU2009I
FQXSPPU2010G
FQXSPPU2011I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0063M
FQXSPPW2008I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0009I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0024I
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2009I
FQXSPUN2010I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2026I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI error messages
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
Lenovo XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
Tech Tips
Security advisories
Hardware disassembling for recycle
Disassemble the system-board assembly for recycle
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem edge servers
ThinkSystem SE350 Types 7Z46, 7D1X, 7D27, 7D1R
Resources and downloads
Server package contents
Features
Specifications
Shock and vibration specifications
Particulate contamination
Management offerings
Server components
Front view
Front operator panel
Rear view
System-board switches, jumpers, and buttons
System-board LEDs
System-board connectors
LOM packages
System-board switches and jumpers
PCIe riser assembly
M.2 drive and slot numbering
Parts list
Power cords
Server hardware setup
Server setup checklist
Installation Guidelines
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Install server hardware options
Remove a compute node
Remove the top cover
Remove the air baffle
Remove the PCIe riser assembly
Remove the front operator panel
Remove the lock position switch
Remove the intrusion switch cable
Install a power adapter
Install the M.2 boot adapter
Install a M.2 data adapter
Install the M.2 WLAN/LTE wireless adapter
Install the SIM card
Install the PCIe adapter
Install the PCIe riser assembly
Install the intrusion switch cable
Install a DIMM
Install the front operator panel
Install the lock position switch
Install the air baffle
Install the top cover
Install a compute node
Install the server in a rack
Cable the server
Power on the server
Validate server setup
Power off the server
System configuration
Activate the system
Lockdown Mode and Motion Detection
Backup the Self Encryption Drive Authentication Key (SED AK)
Set the network connection for the XClarity Controller
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
RAID configuration
Wireless enabled LOM package configuration
Wireless enabled LOM package preset
Embedded switch CLI for wireless LOM Package configuration
Firewall settings
OpenVPN client settings
Back up the server configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Hardware replacement procedures
Installation Guidelines
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Adapter replacement
Remove the M.2 boot adapter
Install the M.2 boot adapter
Remove the M.2 WLAN/LTE wireless adapter
Install the M.2 WLAN/LTE wireless adapter
Remove a M.2 data adapter
Install a M.2 data adapter
Remove the PCIe adapter
Install the PCIe adapter
Air baffle replacement
Remove the air baffle
Install the air baffle
CMOS battery (CR2032) replacement
Remove the CMOS battery (CR2032)
Install the CMOS battery (CR2032)
Compute node replacement
Remove a compute node
Install a compute node
DIMM replacement
Remove a DIMM
Install a DIMM
Dust filter replacement
Remove the dust filter in locking bezel
Install the dust filter in locking bezel
Remove the dust filter in E1 enclosure bracket
Install the dust filter in E1 enclosure bracket
Fan replacement
Remove a fan
Install a fan
Front operator panel replacement
Remove the front operator panel
Install the front operator panel
Heat sink replacement
Remove the heat sink
Install the heat sink
Intrusion switch cable replacement
Remove the intrusion switch cable
Install the intrusion switch cable
Lock position switch replacement
Remove the lock position switch
Install the lock position switch
LTE/WLAN Antenna replacement
Remove a LTE/WLAN Antenna
Install a LTE/WLAN Antenna
M.2 drive on an M.2 data adapter replacement
Remove an M.2 drive from an M.2 data adapter
Install an M.2 drive on an M.2 data adapter
M.2 LTE module replacement
Remove the M.2 LTE module
Install the M.2 LTE module
M.2 WLAN module replacement
Remove the M.2 WLAN module
Install the M.2 WLAN module
PCIe riser assembly replacement
Remove the PCIe riser assembly
Install the PCIe riser assembly
Power distribution module replacement
Remove the power distribution module
Install the power distribution module
Power adapter replacement
Remove a power adapter
Install a power adapter
Rubber feet replacement
Remove the rubber feet
Install the rubber feet
SIM card replacement
Remove the SIM card
Install the SIM card
System board replacement
Remove the system board assembly
Install the system board assembly
Update the machine type and serial number
Enable TPM
Set the TPM policy
Assert Physical Presence
Top cover replacement
Remove the top cover
Install the top cover
TPM card (for Chinese Mainland only) replacement
Remove the TPM card (for Chinese Mainland only)
Install the TPM card (for Chinese Mainland only)
Complete the parts replacement
Problem determination
Event logs
The front operator panel and error LEDs
System-board LEDs
General problem determination procedures
Resolving suspected power problems
Resolving suspected Ethernet controller problems
Troubleshooting by symptom
Power on and power off problems
Memory problems
Monitor and video problems
Keyboard, mouse, or USB-device problems
Optional-device problems
Serial-device problems
Intermittent problems
Power problems
Network problems
Observable problems
Software problems
SIM selection and APN settings (Japan)
Messages
Event and alert message format
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPCA0002M
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2002I
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPCR0001N
FQXSPCR2001I
FQXSPDA2000I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW0000N
FQXSPFW0001N
FQXSPFW0002N
FQXSPFW2001I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0010I
FQXSPIO0011N
FQXSPIO0013N
FQXSPIO0015M
FQXSPIO2002I
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPIO2017I
FQXSPMA0002N
FQXSPMA0005N
FQXSPMA0007L
FQXSPMA0008N
FQXSPMA0009I
FQXSPMA0010J
FQXSPMA0011G
FQXSPMA0012M
FQXSPMA0013N
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2010I
FQXSPMA2012I
FQXSPMA2013I
FQXSPMA2024I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPNM4054I
FQXSPNM4055I
FQXSPNM4056I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0000I
FQXSPPR2001I
FQXSPPU0000I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU0004M
FQXSPPU0007N
FQXSPPU0009N
FQXSPPU0011N
FQXSPPU2000I
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2007I
FQXSPPW0001I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0031J
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0063M
FQXSPPW0110M
FQXSPPW2001I
FQXSPPW2008I
FQXSPPW2031I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPPW2110I
FQXSPPW4001I
FQXSPSB2000I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0005L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2005I
FQXSPSD2007I
FQXSPSE0000F
FQXSPSE2000I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSE4042I
FQXSPSE4043I
FQXSPSE4044I
FQXSPSE4045I
FQXSPSE4046I
FQXSPSE4047I
FQXSPSE4048I
FQXSPSE4049I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPSS4010I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0009I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN2009I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2030I
FQXSPUP0002I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026M
FQXSFMA0027K
FQXSFMA0028K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
Tech Tips
Security advisories
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem SE350 Types 7Z46, 7D1X, 7D27, 7D1R
Resources and downloads
Server package contents
Features
Specifications
Shock and vibration specifications
Particulate contamination
Management offerings
Server components
Front view
Front operator panel
Rear view
System-board switches, jumpers, and buttons
System-board LEDs
System-board connectors
LOM packages
System-board switches and jumpers
PCIe riser assembly
M.2 drive and slot numbering
Parts list
Power cords
Server hardware setup
Server setup checklist
Installation Guidelines
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Install server hardware options
Remove a compute node
Remove the top cover
Remove the air baffle
Remove the PCIe riser assembly
Remove the front operator panel
Remove the lock position switch
Remove the intrusion switch cable
Install a power adapter
Install the M.2 boot adapter
Install a M.2 data adapter
Install the M.2 WLAN/LTE wireless adapter
Install the SIM card
Install the PCIe adapter
Install the PCIe riser assembly
Install the intrusion switch cable
Install a DIMM
Install the front operator panel
Install the lock position switch
Install the air baffle
Install the top cover
Install a compute node
Install the server in a rack
Cable the server
Power on the server
Validate server setup
Power off the server
System configuration
Activate the system
Lockdown Mode and Motion Detection
Backup the Self Encryption Drive Authentication Key (SED AK)
Set the network connection for the XClarity Controller
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
RAID configuration
Wireless enabled LOM package configuration
Wireless enabled LOM package preset
Embedded switch CLI for wireless LOM Package configuration
Firewall settings
OpenVPN client settings
Back up the server configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Hardware replacement procedures
Installation Guidelines
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Adapter replacement
Remove the M.2 boot adapter
Install the M.2 boot adapter
Remove the M.2 WLAN/LTE wireless adapter
Install the M.2 WLAN/LTE wireless adapter
Remove a M.2 data adapter
Install a M.2 data adapter
Remove the PCIe adapter
Install the PCIe adapter
Air baffle replacement
Remove the air baffle
Install the air baffle
CMOS battery (CR2032) replacement
Remove the CMOS battery (CR2032)
Install the CMOS battery (CR2032)
Compute node replacement
Remove a compute node
Install a compute node
DIMM replacement
Remove a DIMM
Install a DIMM
Dust filter replacement
Remove the dust filter in locking bezel
Install the dust filter in locking bezel
Remove the dust filter in E1 enclosure bracket
Install the dust filter in E1 enclosure bracket
Fan replacement
Remove a fan
Install a fan
Front operator panel replacement
Remove the front operator panel
Install the front operator panel
Heat sink replacement
Remove the heat sink
Install the heat sink
Intrusion switch cable replacement
Remove the intrusion switch cable
Install the intrusion switch cable
Lock position switch replacement
Remove the lock position switch
Install the lock position switch
LTE/WLAN Antenna replacement
Remove a LTE/WLAN Antenna
Install a LTE/WLAN Antenna
M.2 drive on an M.2 data adapter replacement
Remove an M.2 drive from an M.2 data adapter
Install an M.2 drive on an M.2 data adapter
M.2 LTE module replacement
Remove the M.2 LTE module
Install the M.2 LTE module
M.2 WLAN module replacement
Remove the M.2 WLAN module
Install the M.2 WLAN module
PCIe riser assembly replacement
Remove the PCIe riser assembly
Install the PCIe riser assembly
Power distribution module replacement
Remove the power distribution module
Install the power distribution module
Power adapter replacement
Remove a power adapter
Install a power adapter
Rubber feet replacement
Remove the rubber feet
Install the rubber feet
SIM card replacement
Remove the SIM card
Install the SIM card
System board replacement
Remove the system board assembly
Install the system board assembly
Update the machine type and serial number
Enable TPM
Set the TPM policy
Assert Physical Presence
Top cover replacement
Remove the top cover
Install the top cover
TPM card (for Chinese Mainland only) replacement
Remove the TPM card (for Chinese Mainland only)
Install the TPM card (for Chinese Mainland only)
Complete the parts replacement
Problem determination
Event logs
The front operator panel and error LEDs
System-board LEDs
General problem determination procedures
Resolving suspected power problems
Resolving suspected Ethernet controller problems
Troubleshooting by symptom
Power on and power off problems
Memory problems
Monitor and video problems
Keyboard, mouse, or USB-device problems
Optional-device problems
Serial-device problems
Intermittent problems
Power problems
Network problems
Observable problems
Software problems
SIM selection and APN settings (Japan)
Messages
Event and alert message format
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPCA0002M
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2002I
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPCR0001N
FQXSPCR2001I
FQXSPDA2000I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW0000N
FQXSPFW0001N
FQXSPFW0002N
FQXSPFW2001I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0010I
FQXSPIO0011N
FQXSPIO0013N
FQXSPIO0015M
FQXSPIO2002I
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPIO2017I
FQXSPMA0002N
FQXSPMA0005N
FQXSPMA0007L
FQXSPMA0008N
FQXSPMA0009I
FQXSPMA0010J
FQXSPMA0011G
FQXSPMA0012M
FQXSPMA0013N
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2010I
FQXSPMA2012I
FQXSPMA2013I
FQXSPMA2024I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPNM4054I
FQXSPNM4055I
FQXSPNM4056I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0000I
FQXSPPR2001I
FQXSPPU0000I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU0004M
FQXSPPU0007N
FQXSPPU0009N
FQXSPPU0011N
FQXSPPU2000I
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2007I
FQXSPPW0001I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0031J
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0063M
FQXSPPW0110M
FQXSPPW2001I
FQXSPPW2008I
FQXSPPW2031I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPPW2110I
FQXSPPW4001I
FQXSPSB2000I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0005L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2005I
FQXSPSD2007I
FQXSPSE0000F
FQXSPSE2000I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSE4042I
FQXSPSE4043I
FQXSPSE4044I
FQXSPSE4045I
FQXSPSE4046I
FQXSPSE4047I
FQXSPSE4048I
FQXSPSE4049I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPSS4010I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0009I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN2009I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2030I
FQXSPUP0002I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026M
FQXSFMA0027K
FQXSFMA0028K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
Tech Tips
Security advisories
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem high-density servers
ThinkSystem SD530 Types 7X20, 7X21, 7X22
Resources and downloads
Solution package contents
Features
Specifications
Enclosure specifications
Compute node specifications
PCIe expansion node specifications
Particulate contamination
Management options
Solution components
Front view
Enclosure
Compute node
Node operator panel
Rear view
System Management Module (SMM)
PCIe slot LEDs
Modular 6U configuration
System board layout
System-board internal connectors
System-board switches
KVM breakout cable
2.5-inch drive backplanes
Parts list
Enclosure components
Compute node components
PCIe expansion node components
Power cords
Internal cable routing
Four 2.5-inch-drive model
Four 2.5-inch-drive NVMe model
Six 2.5-inch-drive model
Six 2.5-inch-drive model (with NVMe)
KVM breakout module
PCIe expansion node
Modular enclosure for 6U configuration
Solution hardware setup
Solution setup checklist
Installation Guidelines
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Install solution hardware options
Install hardware options in the enclosure
Remove the shuttle
Remove the EIOM
Install a low-profile PCIe x16 adapter
Install a low-profile PCIe x8 adapter
Install a low-profile PCIe x8 adapter in PCIe slot 3-B and 4-B
Install a hot-swap power supply
Install the EIOM
Install the shuttle
Install the cable management arm
Install hardware options in the compute node
Remove a compute node from the enclosure
Remove the compute node cover
Remove the air baffle
Remove the M.2 backplane
Install an M.2 drive in the M.2 backplane
How to adjust the position of the retainer on the M.2 backplane
Install the KVM breakout module
Install a hot-swap drive
Install a memory module
DC Persistent Memory Module (DCPMM) setup
Adding memory modules with DCPMMs
Memory module installation order
DRAM DIMM installation order
DCPMM and DRAM DIMM installation order
DCPMM installation: App Direct Mode
DCPMM installation: Memory Mode
DCPMM installation: Mixed Memory Mode
Install a memory module
Install a RAID adapter into the compute node
Install the M.2 backplane
Install a processor-heat-sink module
Install the air baffle
Install the compute node cover
Install a compute node in the enclosure
Install hardware options in the PCIe expansion node
Remove the compute-expansion node assembly from the enclosure
Remove the rear cable cover
Install a PCIe adapter into the riser cage
Install a PCIe riser assembly into the PCIe expansion node assembly
Install the rear cable cover
Install the compute-expansion node assembly into the enclosure
Install the enclosure in a rack
Install slide rails into the rack
Install the enclosure on the slide rails
Slide the enclosure into the rack
Secure the enclosure in the rack for shipping
Install the cable management arm
Connect and route cables
Remove the cable management arm
Change the cable management arm for installation tothe other side of the rack
Cable the solution
Power on the compute node
Validate solution setup
Power off the compute node
System configuration
Set the network connection for the Lenovo XClarity Controller
Set front USB port for Lenovo XClarity Controller connection
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
Configure DC Persistent Memory Module (DCPMM)
RAID configuration
Deploy the operating system
Back up the solution configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
System Management Module
Introduction
Web interface access
Overview
Summary
Enclosure front overview
Enclosure rear overview
Power
Power overview
Power supply unit configuration
Power cap
Voltage Overview
Power Restore Policy
Cooling
Cooling Overview
Power supply unit Fan Speed
Acoustic Mode
System Information
Enclosure VPD
PDM VPD
SMM VPD
Power supply unit VPD
EIOM VPD
PIOR Right/Left VPD
Event Log
Configuration
Firmware Update
SMTP/SNMP/PEF
Network Configuration
Time Setting
User Account
Account Security
Services
Web Certificate
Network Time Protocol (NTP)
Backup and Restore
IPMI command
IPMI command contents
SMTP configuration parameters
LAN configuration parameters
NTP configuration parameters
Hardware replacement procedures
Installation Guidelines
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Replace components in the enclosure
Cable management arm replacement
Remove the cable management arm
Install the cable management arm
Compute node replacement
Remove a compute node from the enclosure
Replace a compute node
Install a compute node in the enclosure
Update the machine type and serial number
Enable TPM/TCM
Set the TPM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
Trusted Cryptographic Module (TCM) replacement
Remove the Trusted Cryptographic Module (TCM)
Install the Trusted Cryptographic Module (TCM)
Compute-expansion node assembly replacement
Remove the compute-expansion node assembly from the enclosure
Install the compute-expansion node assembly into the enclosure
EIOM replacement
Remove the EIOM
Install the EIOM
Fan replacement
Remove a fan
Install a fan
Fan cover replacement
Remove the fan cover
Install the fan cover
Hot-swap power supply replacement
Remove a hot-swap power supply
Install a hot-swap power supply
Low-profile PCIe x8 adapter replacement
Remove a low-profile PCIe x8 adapter
Remove a low-profile PCIe x8 adapter in PCIe slot 3-B and 4-B
Install a low-profile PCIe x8 adapter
Install a low-profile PCIe x8 adapter in PCIe slot 3-B and 4-B
Low-profile PCIe x16 adapter replacement
Remove a low-profile PCIe x16 adapter
Install a low-profile PCIe x16 adapter
PCIe I/O riser (PIOR) replacement
Remove the PIOR left/right
Install the PIOR left/right
Shared PCIe dual adapters replacement
Remove the shared PCIe dual adapters
Install the shared PCIe dual adapters
Shuttle replacement
Remove the shuttle
Install the shuttle
System Management Module (SMM) and related component replacement
Remove the System Management Module (SMM)
Install the System Management Module (SMM)
Device installation and removal for SMM data backup and restore
USB flash drive removal and installation for single Ethernet port SMM
MicroSD card removal and installation for dual Ethernet port SMM
CMOS battery replacement for SMM
Remove the CMOS battery from the SMM
Install the CMOS battery into the SMM
Replace components in the compute node
Air baffle replacement
Remove the air baffle
Install the air baffle
CMOS battery (CR2032) replacement
Remove the CMOS battery
Install the CMOS battery (CR2032)
Compute node cover replacement
Remove the compute node cover
Install the compute node cover
Memory module replacement
Remove a memory module
Install a memory module
Drive replacement
Remove a hot-swap drive
Install a hot-swap drive
Drive backplane replacement
Remove the drive backplane
Install the drive backplane
Drive bay blank replacement
Remove a drive bay blank
Install a drive bay blank
KVM breakout module replacement
Remove the KVM breakout module
Install the KVM breakout module
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement in the M.2 backplane
Remove an M.2 drive in the M.2 backplane
Install an M.2 drive in the M.2 backplane
How to adjust the position of the retainer on the M.2 backplane
Processor and heat sink replacement
Remove a processor and heat sink
Install a processor and heat sink
RAID adapter replacement
Remove a RAID adapter from the compute node
Install a RAID adapter into the compute node
Replace components in the PCIe expansion node
PCIe adapter replacement
Remove a PCIe adapter from the riser cage
Install a PCIe adapter into the riser cage
PCIe riser assembly replacement
Remove a PCIe riser assembly from the compute-expansion node assembly
Install a PCIe riser assembly into the PCIe expansion node assembly
PCIe expansion node disengagement/re-engagement
Disengage the PCIe expansion node from a compute node
Re-engage the PCIe expansion node to a compute node
PCIe expansion node replacement
Remove the PCIe expansion node from a compute node
Install the PCIe expansion node to a compute node
PCIe expansion node power board replacement
Remove the PCIe expansion node power board
Install the PCIe expansion node power board
Rear cable cover replacement
Remove the rear cable cover
Install the rear cable cover
Complete the parts replacement
Problem determination
Event logs
Collecting event logs
Checking POST status
Node operator panel
Power supply LEDs
General problem determination procedures
Resolving suspected power problems
Resolving suspected Ethernet controller problems
Troubleshooting by symptom:
Drive problems
EIOM card problems
Intermittent problems
Keyboard, mouse, or USB-device problems
Memory problems
Monitor and video problems
Network problems
Observable problems
Optional-device problems
Power on and power off problems
Serial-device problems
Software problems
System Management Module problems
Messages
Event and alert message format
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0002M
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2002I
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW2001I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0011N
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPMA0010J
FQXSPMA0012M
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2010I
FQXSPMA2012I
FQXSPMA2013I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0000I
FQXSPPR2001I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU2001I
FQXSPPU2002I
FQXSPPW0001I
FQXSPPW0002L
FQXSPPW0003G
FQXSPPW0005I
FQXSPPW0006I
FQXSPPW0007L
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0031J
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0057J
FQXSPPW0061M
FQXSPPW0063M
FQXSPPW2001I
FQXSPPW2002I
FQXSPPW2003I
FQXSPPW2005I
FQXSPPW2006I
FQXSPPW2007I
FQXSPPW2008I
FQXSPPW2031I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2057I
FQXSPPW2061I
FQXSPPW2063I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0017I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0027I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2009I
FQXSPUN2010I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
SMM events
0201001A
0201001B
0201001C
0201001D
0201001E
0201001F
0201021A
0201021B
0201021C
0201021D
0201021E
0201021F
02010220
0201071A
0201071B
0201071C
0201071D
0201071E
0201071F
0201091A
0201091B
0201091C
0201091D
0201091E
0201091F
04010010
04010011
04010012
04010013
04010014
04010015
04010016
04010017
04010018
04010019
04010210
04010211
04010212
04010213
04010214
04010215
04010216
04010217
04010218
04010219
040701CA
040800B0
040800B1
040800B2
040800B3
040800B4
080701AA
080701CB
080701D8
080701D9
080701E8
080701E9
080702E2
080707A4
080707A5
080708A8
080708A9
080708AB
080801E0
080801E1
086F0180
086F0181
086F0182
086F0183
086F0184
086F0185
086F0186
086F0187
086F0188
086F0189
086F018A
086F018B
086F018C
086F018D
086F018E
086F018F
086F0190
086F0191
086F019A
086F019B
086F019C
086F019D
086F01A0
086F01A1
086F01A6
086F01A7
086F01AC
086F01AD
086F01AE
086F01AF
086F03E0
086F03E1
086F06E0
086F06E1
106F0202
106F0402
106F0502
126F0404
146F0231
146F0232
1509002D
1509002E
15090035
15090036
15090037
180702C0
180702C1
180702D0
180702D2
180702D3
180702D6
180702D7
180708CE
1D6F0030
21070150
21070151
21070152
21070153
21070154
21070155
21070156
21070157
21070164
21070165
21070166
21070167
2107023B
2107023C
2107023E
2107023F
21070668
21070669
2107066A
2107066B
21070670
21070671
21070672
21070673
21070844
21070845
21070846
21070847
21070848
21070849
2107084A
2107084B
2107084C
2107084D
2107084E
2107084F
21070878
21070879
2107087A
2107087B
21080140
21080141
21080142
21080143
216F0058
216F0059
216F005A
216F005B
216F005C
216F005D
216F005E
216F005F
216F0060
216F0061
216F0062
216F0063
216F0074
216F0075
216F0076
216F0077
256F0138
2B6F0139
Tech Tips
Security advisories
Hardware disassembling for recycle
Disassemble the compute node for recycle
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem SD650 Type 7X58
PDF files
Solution package contents
Features
Specifications
Particulate contamination
Management options
Solution components
Front view
Rear view
Fan power control (FPC) module
Power supplies
System board layout
System-board internal connectors
System-board LEDs
System-board switches
Internal cable routing
2.5-inch drive models
Internal Faceplate Transition (IFT) adapter
Parts list
Power cords
Solution hardware setup
Solution setup checklist
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Install solution hardware options
Remove a DWC tray from the enclosure
Remove the tray cover
Remove a DIMM
Remove a drive
Remove the M.2 backplane
Remove an adapter
Remove an Internal Faceplate Transition (IFT) adapter
Memory module installation
Install a DIMM
DRAM Installation order
DC Persistent Memory Module (DCPMM) installation order
DC Persistent Memory Module (DCPMM) setup
Adding memory modules with DCPMMs
Install an M.2 drive into the M.2 backplane
Install the M.2 backplane
Install a drive
Install an adapter
Install an Internal Faceplate Transition (IFT) adapter
Install the tray cover
Install a in the enclosure
Install the enclosure in a rack
Cable the enclosure
Power on nodes
Power off nodes
System configuration
Set the network connection for the Lenovo XClarity Controller
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
Configure DC Persistent Memory Module (DCPMM)
RAID configuration
Back up the solution configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Fan and Power Control
Introduction
Web interface access
Overview
Summary
Chassis Front Overview
Chassis Rear Overview
Power
Power Overview
PSU Configuration
Power Capping
Voltage Overview
Power Restore Policy
Cooling
Cooling Overview
PSU Fan Speed
Acoustic Mode
System Information
Chassis VPD
Midplane VPD
FPC VPD
PSU VPD
Event Log
USB Recovery
Configuration
Firmware Update
SMTP/SNMP/PEF
Network Configuration
Time Setting
User Account
Web Service
Web Certificate
IPMI Command
Hardware replacement procedures
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Replace components in the enclosure
Enclosure midplane replacement
Remove the enclosure midplane
Install the enclosure midplane
Drip sensor assembly replacement
Remove the drip sensor assembly
Install the drip sensor assembly
Fan power control (FPC) replacement
Remove the FPC
Install the FPC
FPC battery replacement
Remove the FPC battery
Install the FPC battery
Hot-swap power supply replacement
Remove a hot-swap power supply
Install a hot-swap power supply
Manifold replacement
Remove the manifold
Install the manifold
Replace components in the tray
CMOS battery (CR2032) replacement
Remove the CMOS battery
Install the CMOS battery (CR2032)
DIMM replacement
Remove a DIMM
Memory module installation
Install a DIMM
Drive replacement
Remove a drive
Install a drive
Drive cage assembly replacement
Remove a drive cage assembly
Install a drive cage assembly
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement
Remove an M.2 drive from the M.2 backplane
Install an M.2 drive into the M.2 backplane
How to adjust the position of the retainer on the M.2 backplane
PCIe adapter replacement
Remove an adapter
Install an adapter
Remove an Internal Faceplate Transition (IFT) adapter
Install an Internal Faceplate Transition (IFT) adapter
Power distribution board replacement
Remove the power distribution board
Install the power distribution board
Processor replacement
Remove a processor
Install a processor
System board replacement
Remove a system board
Install a system board
Update the machine type and serial number
Enable TPM/TCM
Set the TPM/TCM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
Tray cover replacement
Remove the tray cover
Install the tray cover
TCM/TPM adapter replacement (for Chinese Mainland only)
Remove the TCM/TPM adapter (for Chinese Mainland only)
Install the TCM/TPM adapter (for Chinese Mainland only)
Water loop replacement
Remove the water loop
Install the water loop
DWC tray replacement
Remove a DWC tray from the enclosure
Install a in the enclosure
Complete the parts replacement
Problem determination
Event logs
Light path diagnostics
Power supply LEDs
System-board LEDs
Fan power control (FPC) module
Drip sensor LED
General problem determination procedures
Resolving suspected power problems
Resolving suspected Ethernet controller problems
Troubleshooting by symptom
Power on and power off problems
Memory problems
Hard disk drive problems
Water leak problems
Monitor and video problems
Keyboard, mouse, or USB-device problems
Optional-device problems
Serial-device problems
Intermittent problems
Network problems
Observable problems
Software problems
Messages
Event and alert message format
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0002M
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0013I
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW2001I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0010I
FQXSPIO0011N
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPMA0003I
FQXSPMA0010J
FQXSPMA0012M
FQXSPMA2003I
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2010I
FQXSPMA2012I
FQXSPMA2013I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0000I
FQXSPPR2001I
FQXSPPU0000I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU2000I
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2003I
FQXSPPU2004I
FQXSPPW0001I
FQXSPPW0002L
FQXSPPW0006I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0031J
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0055I
FQXSPPW0057J
FQXSPPW0063M
FQXSPPW0088J
FQXSPPW2001I
FQXSPPW2002I
FQXSPPW2006I
FQXSPPW2008I
FQXSPPW2031I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0017I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
FPC events
02
03
04
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
30
31
32
33
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
E0
E1
Tech Tips
Security advisories
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
Management Tools
FPC
SMM
Introduction
Web interface access
Overview
Summary
Enclosure front overview
Enclosure rear overview
Power
Power overview
Power supply unit configuration
Power cap
Voltage Overview
Power Restore Policy
Cooling
Cooling Overview
Power supply unit Fan Speed
Acoustic Mode
System Information
Enclosure VPD
PDM VPD
SMM VPD
Power supply unit VPD
EIOM VPD
PIOR Right/Left VPD
Event Log
Configuration
Firmware Update
SMTP/SNMP/PEF
Network Configuration
Time Setting
User Account
Account Security
Services
Web Certificate
Network Time Protocol (NTP)
Backup and Restore
IPMI command
IPMI command contents
SMTP configuration parameters
LAN configuration parameters
NTP configuration parameters
ThinkSystem SD530 Types 7X20, 7X21, 7X22
Resources and downloads
Solution package contents
Features
Specifications
Enclosure specifications
Compute node specifications
PCIe expansion node specifications
Particulate contamination
Management options
Solution components
Front view
Enclosure
Compute node
Node operator panel
Rear view
System Management Module (SMM)
PCIe slot LEDs
Modular 6U configuration
System board layout
System-board internal connectors
System-board switches
KVM breakout cable
2.5-inch drive backplanes
Parts list
Enclosure components
Compute node components
PCIe expansion node components
Power cords
Internal cable routing
Four 2.5-inch-drive model
Four 2.5-inch-drive NVMe model
Six 2.5-inch-drive model
Six 2.5-inch-drive model (with NVMe)
KVM breakout module
PCIe expansion node
Modular enclosure for 6U configuration
Solution hardware setup
Solution setup checklist
Installation Guidelines
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Install solution hardware options
Install hardware options in the enclosure
Remove the shuttle
Remove the EIOM
Install a low-profile PCIe x16 adapter
Install a low-profile PCIe x8 adapter
Install a low-profile PCIe x8 adapter in PCIe slot 3-B and 4-B
Install a hot-swap power supply
Install the EIOM
Install the shuttle
Install the cable management arm
Install hardware options in the compute node
Remove a compute node from the enclosure
Remove the compute node cover
Remove the air baffle
Remove the M.2 backplane
Install an M.2 drive in the M.2 backplane
How to adjust the position of the retainer on the M.2 backplane
Install the KVM breakout module
Install a hot-swap drive
Install a memory module
DC Persistent Memory Module (DCPMM) setup
Adding memory modules with DCPMMs
Memory module installation order
DRAM DIMM installation order
DCPMM and DRAM DIMM installation order
DCPMM installation: App Direct Mode
DCPMM installation: Memory Mode
DCPMM installation: Mixed Memory Mode
Install a memory module
Install a RAID adapter into the compute node
Install the M.2 backplane
Install a processor-heat-sink module
Install the air baffle
Install the compute node cover
Install a compute node in the enclosure
Install hardware options in the PCIe expansion node
Remove the compute-expansion node assembly from the enclosure
Remove the rear cable cover
Install a PCIe adapter into the riser cage
Install a PCIe riser assembly into the PCIe expansion node assembly
Install the rear cable cover
Install the compute-expansion node assembly into the enclosure
Install the enclosure in a rack
Install slide rails into the rack
Install the enclosure on the slide rails
Slide the enclosure into the rack
Secure the enclosure in the rack for shipping
Install the cable management arm
Connect and route cables
Remove the cable management arm
Change the cable management arm for installation tothe other side of the rack
Cable the solution
Power on the compute node
Validate solution setup
Power off the compute node
System configuration
Set the network connection for the Lenovo XClarity Controller
Set front USB port for Lenovo XClarity Controller connection
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
Configure DC Persistent Memory Module (DCPMM)
RAID configuration
Deploy the operating system
Back up the solution configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
System Management Module
Introduction
Web interface access
Overview
Summary
Enclosure front overview
Enclosure rear overview
Power
Power overview
Power supply unit configuration
Power cap
Voltage Overview
Power Restore Policy
Cooling
Cooling Overview
Power supply unit Fan Speed
Acoustic Mode
System Information
Enclosure VPD
PDM VPD
SMM VPD
Power supply unit VPD
EIOM VPD
PIOR Right/Left VPD
Event Log
Configuration
Firmware Update
SMTP/SNMP/PEF
Network Configuration
Time Setting
User Account
Account Security
Services
Web Certificate
Network Time Protocol (NTP)
Backup and Restore
IPMI command
IPMI command contents
SMTP configuration parameters
LAN configuration parameters
NTP configuration parameters
Hardware replacement procedures
Installation Guidelines
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Replace components in the enclosure
Cable management arm replacement
Remove the cable management arm
Install the cable management arm
Compute node replacement
Remove a compute node from the enclosure
Replace a compute node
Install a compute node in the enclosure
Update the machine type and serial number
Enable TPM/TCM
Set the TPM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
Trusted Cryptographic Module (TCM) replacement
Remove the Trusted Cryptographic Module (TCM)
Install the Trusted Cryptographic Module (TCM)
Compute-expansion node assembly replacement
Remove the compute-expansion node assembly from the enclosure
Install the compute-expansion node assembly into the enclosure
EIOM replacement
Remove the EIOM
Install the EIOM
Fan replacement
Remove a fan
Install a fan
Fan cover replacement
Remove the fan cover
Install the fan cover
Hot-swap power supply replacement
Remove a hot-swap power supply
Install a hot-swap power supply
Low-profile PCIe x8 adapter replacement
Remove a low-profile PCIe x8 adapter
Remove a low-profile PCIe x8 adapter in PCIe slot 3-B and 4-B
Install a low-profile PCIe x8 adapter
Install a low-profile PCIe x8 adapter in PCIe slot 3-B and 4-B
Low-profile PCIe x16 adapter replacement
Remove a low-profile PCIe x16 adapter
Install a low-profile PCIe x16 adapter
PCIe I/O riser (PIOR) replacement
Remove the PIOR left/right
Install the PIOR left/right
Shared PCIe dual adapters replacement
Remove the shared PCIe dual adapters
Install the shared PCIe dual adapters
Shuttle replacement
Remove the shuttle
Install the shuttle
System Management Module (SMM) and related component replacement
Remove the System Management Module (SMM)
Install the System Management Module (SMM)
Device installation and removal for SMM data backup and restore
USB flash drive removal and installation for single Ethernet port SMM
MicroSD card removal and installation for dual Ethernet port SMM
CMOS battery replacement for SMM
Remove the CMOS battery from the SMM
Install the CMOS battery into the SMM
Replace components in the compute node
Air baffle replacement
Remove the air baffle
Install the air baffle
CMOS battery (CR2032) replacement
Remove the CMOS battery
Install the CMOS battery (CR2032)
Compute node cover replacement
Remove the compute node cover
Install the compute node cover
Memory module replacement
Remove a memory module
Install a memory module
Drive replacement
Remove a hot-swap drive
Install a hot-swap drive
Drive backplane replacement
Remove the drive backplane
Install the drive backplane
Drive bay blank replacement
Remove a drive bay blank
Install a drive bay blank
KVM breakout module replacement
Remove the KVM breakout module
Install the KVM breakout module
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement in the M.2 backplane
Remove an M.2 drive in the M.2 backplane
Install an M.2 drive in the M.2 backplane
How to adjust the position of the retainer on the M.2 backplane
Processor and heat sink replacement
Remove a processor and heat sink
Install a processor and heat sink
RAID adapter replacement
Remove a RAID adapter from the compute node
Install a RAID adapter into the compute node
Replace components in the PCIe expansion node
PCIe adapter replacement
Remove a PCIe adapter from the riser cage
Install a PCIe adapter into the riser cage
PCIe riser assembly replacement
Remove a PCIe riser assembly from the compute-expansion node assembly
Install a PCIe riser assembly into the PCIe expansion node assembly
PCIe expansion node disengagement/re-engagement
Disengage the PCIe expansion node from a compute node
Re-engage the PCIe expansion node to a compute node
PCIe expansion node replacement
Remove the PCIe expansion node from a compute node
Install the PCIe expansion node to a compute node
PCIe expansion node power board replacement
Remove the PCIe expansion node power board
Install the PCIe expansion node power board
Rear cable cover replacement
Remove the rear cable cover
Install the rear cable cover
Complete the parts replacement
Problem determination
Event logs
Collecting event logs
Checking POST status
Node operator panel
Power supply LEDs
General problem determination procedures
Resolving suspected power problems
Resolving suspected Ethernet controller problems
Troubleshooting by symptom:
Drive problems
EIOM card problems
Intermittent problems
Keyboard, mouse, or USB-device problems
Memory problems
Monitor and video problems
Network problems
Observable problems
Optional-device problems
Power on and power off problems
Serial-device problems
Software problems
System Management Module problems
Messages
Event and alert message format
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0002M
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2002I
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW2001I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0011N
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPMA0010J
FQXSPMA0012M
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2010I
FQXSPMA2012I
FQXSPMA2013I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0000I
FQXSPPR2001I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU2001I
FQXSPPU2002I
FQXSPPW0001I
FQXSPPW0002L
FQXSPPW0003G
FQXSPPW0005I
FQXSPPW0006I
FQXSPPW0007L
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0031J
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0057J
FQXSPPW0061M
FQXSPPW0063M
FQXSPPW2001I
FQXSPPW2002I
FQXSPPW2003I
FQXSPPW2005I
FQXSPPW2006I
FQXSPPW2007I
FQXSPPW2008I
FQXSPPW2031I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2057I
FQXSPPW2061I
FQXSPPW2063I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0017I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0027I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2009I
FQXSPUN2010I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
SMM events
0201001A
0201001B
0201001C
0201001D
0201001E
0201001F
0201021A
0201021B
0201021C
0201021D
0201021E
0201021F
02010220
0201071A
0201071B
0201071C
0201071D
0201071E
0201071F
0201091A
0201091B
0201091C
0201091D
0201091E
0201091F
04010010
04010011
04010012
04010013
04010014
04010015
04010016
04010017
04010018
04010019
04010210
04010211
04010212
04010213
04010214
04010215
04010216
04010217
04010218
04010219
040701CA
040800B0
040800B1
040800B2
040800B3
040800B4
080701AA
080701CB
080701D8
080701D9
080701E8
080701E9
080702E2
080707A4
080707A5
080708A8
080708A9
080708AB
080801E0
080801E1
086F0180
086F0181
086F0182
086F0183
086F0184
086F0185
086F0186
086F0187
086F0188
086F0189
086F018A
086F018B
086F018C
086F018D
086F018E
086F018F
086F0190
086F0191
086F019A
086F019B
086F019C
086F019D
086F01A0
086F01A1
086F01A6
086F01A7
086F01AC
086F01AD
086F01AE
086F01AF
086F03E0
086F03E1
086F06E0
086F06E1
106F0202
106F0402
106F0502
126F0404
146F0231
146F0232
1509002D
1509002E
15090035
15090036
15090037
180702C0
180702C1
180702D0
180702D2
180702D3
180702D6
180702D7
180708CE
1D6F0030
21070150
21070151
21070152
21070153
21070154
21070155
21070156
21070157
21070164
21070165
21070166
21070167
2107023B
2107023C
2107023E
2107023F
21070668
21070669
2107066A
2107066B
21070670
21070671
21070672
21070673
21070844
21070845
21070846
21070847
21070848
21070849
2107084A
2107084B
2107084C
2107084D
2107084E
2107084F
21070878
21070879
2107087A
2107087B
21080140
21080141
21080142
21080143
216F0058
216F0059
216F005A
216F005B
216F005C
216F005D
216F005E
216F005F
216F0060
216F0061
216F0062
216F0063
216F0074
216F0075
216F0076
216F0077
256F0138
2B6F0139
Tech Tips
Security advisories
Hardware disassembling for recycle
Disassemble the compute node for recycle
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
ThinkSystem SD650 Type 7X58
PDF files
Solution package contents
Features
Specifications
Particulate contamination
Management options
Solution components
Front view
Rear view
Fan power control (FPC) module
Power supplies
System board layout
System-board internal connectors
System-board LEDs
System-board switches
Internal cable routing
2.5-inch drive models
Internal Faceplate Transition (IFT) adapter
Parts list
Power cords
Solution hardware setup
Solution setup checklist
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Install solution hardware options
Remove a DWC tray from the enclosure
Remove the tray cover
Remove a DIMM
Remove a drive
Remove the M.2 backplane
Remove an adapter
Remove an Internal Faceplate Transition (IFT) adapter
Memory module installation
Install a DIMM
DRAM Installation order
DC Persistent Memory Module (DCPMM) installation order
DC Persistent Memory Module (DCPMM) setup
Adding memory modules with DCPMMs
Install an M.2 drive into the M.2 backplane
Install the M.2 backplane
Install a drive
Install an adapter
Install an Internal Faceplate Transition (IFT) adapter
Install the tray cover
Install a in the enclosure
Install the enclosure in a rack
Cable the enclosure
Power on nodes
Power off nodes
System configuration
Set the network connection for the Lenovo XClarity Controller
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
Configure DC Persistent Memory Module (DCPMM)
RAID configuration
Back up the solution configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Fan and Power Control
Introduction
Web interface access
Overview
Summary
Chassis Front Overview
Chassis Rear Overview
Power
Power Overview
PSU Configuration
Power Capping
Voltage Overview
Power Restore Policy
Cooling
Cooling Overview
PSU Fan Speed
Acoustic Mode
System Information
Chassis VPD
Midplane VPD
FPC VPD
PSU VPD
Event Log
USB Recovery
Configuration
Firmware Update
SMTP/SNMP/PEF
Network Configuration
Time Setting
User Account
Web Service
Web Certificate
IPMI Command
Hardware replacement procedures
Installation Guidelines
Safety inspection checklist
System reliability guidelines
Working inside the solution with the power on
Handling static-sensitive devices
Replace components in the enclosure
Enclosure midplane replacement
Remove the enclosure midplane
Install the enclosure midplane
Drip sensor assembly replacement
Remove the drip sensor assembly
Install the drip sensor assembly
Fan power control (FPC) replacement
Remove the FPC
Install the FPC
FPC battery replacement
Remove the FPC battery
Install the FPC battery
Hot-swap power supply replacement
Remove a hot-swap power supply
Install a hot-swap power supply
Manifold replacement
Remove the manifold
Install the manifold
Replace components in the tray
CMOS battery (CR2032) replacement
Remove the CMOS battery
Install the CMOS battery (CR2032)
DIMM replacement
Remove a DIMM
Memory module installation
Install a DIMM
Drive replacement
Remove a drive
Install a drive
Drive cage assembly replacement
Remove a drive cage assembly
Install a drive cage assembly
M.2 backplane replacement
Remove the M.2 backplane
Install the M.2 backplane
M.2 drive replacement
Remove an M.2 drive from the M.2 backplane
Install an M.2 drive into the M.2 backplane
How to adjust the position of the retainer on the M.2 backplane
PCIe adapter replacement
Remove an adapter
Install an adapter
Remove an Internal Faceplate Transition (IFT) adapter
Install an Internal Faceplate Transition (IFT) adapter
Power distribution board replacement
Remove the power distribution board
Install the power distribution board
Processor replacement
Remove a processor
Install a processor
System board replacement
Remove a system board
Install a system board
Update the machine type and serial number
Enable TPM/TCM
Set the TPM/TCM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
Tray cover replacement
Remove the tray cover
Install the tray cover
TCM/TPM adapter replacement (for Chinese Mainland only)
Remove the TCM/TPM adapter (for Chinese Mainland only)
Install the TCM/TPM adapter (for Chinese Mainland only)
Water loop replacement
Remove the water loop
Install the water loop
DWC tray replacement
Remove a DWC tray from the enclosure
Install a in the enclosure
Complete the parts replacement
Problem determination
Event logs
Light path diagnostics
Power supply LEDs
System-board LEDs
Fan power control (FPC) module
Drip sensor LED
General problem determination procedures
Resolving suspected power problems
Resolving suspected Ethernet controller problems
Troubleshooting by symptom
Power on and power off problems
Memory problems
Hard disk drive problems
Water leak problems
Monitor and video problems
Keyboard, mouse, or USB-device problems
Optional-device problems
Serial-device problems
Intermittent problems
Network problems
Observable problems
Software problems
Messages
Event and alert message format
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPBT0007I
FQXSPCA0002M
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0013I
FQXSPCA0015J
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2015I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
FQXSPEM4024I
FQXSPEM4025I
FQXSPEM4026I
FQXSPEM4027I
FQXSPEM4028I
FQXSPEM4029I
FQXSPEM4030I
FQXSPFC4000I
FQXSPFC4001I
FQXSPFC4002I
FQXSPFC4003I
FQXSPFC4004I
FQXSPFC4005I
FQXSPFW2001I
FQXSPIO0003N
FQXSPIO0004L
FQXSPIO0006N
FQXSPIO0010I
FQXSPIO0011N
FQXSPIO2003I
FQXSPIO2004I
FQXSPIO2006I
FQXSPIO2010I
FQXSPMA0003I
FQXSPMA0010J
FQXSPMA0012M
FQXSPMA2003I
FQXSPMA2005I
FQXSPMA2007I
FQXSPMA2010I
FQXSPMA2012I
FQXSPMA2013I
FQXSPNM4000I
FQXSPNM4001I
FQXSPNM4002I
FQXSPNM4003I
FQXSPNM4004I
FQXSPNM4005I
FQXSPNM4006I
FQXSPNM4007I
FQXSPNM4008I
FQXSPNM4009I
FQXSPNM4010I
FQXSPNM4011I
FQXSPNM4012I
FQXSPNM4013I
FQXSPNM4014I
FQXSPNM4015I
FQXSPNM4016I
FQXSPNM4017I
FQXSPNM4018I
FQXSPNM4019I
FQXSPNM4020I
FQXSPNM4021I
FQXSPNM4022I
FQXSPNM4023I
FQXSPNM4024I
FQXSPNM4025I
FQXSPNM4026I
FQXSPNM4027I
FQXSPNM4028I
FQXSPNM4029I
FQXSPNM4030I
FQXSPNM4031I
FQXSPNM4032I
FQXSPNM4033I
FQXSPNM4034I
FQXSPNM4035I
FQXSPNM4036I
FQXSPNM4037I
FQXSPNM4038I
FQXSPNM4039I
FQXSPNM4040I
FQXSPNM4041I
FQXSPNM4042I
FQXSPNM4043I
FQXSPNM4044I
FQXSPNM4045I
FQXSPNM4046I
FQXSPNM4047I
FQXSPNM4048I
FQXSPNM4049I
FQXSPNM4050I
FQXSPNM4051I
FQXSPNM4052I
FQXSPNM4053I
FQXSPOS4000I
FQXSPOS4001I
FQXSPOS4002I
FQXSPOS4003I
FQXSPOS4004I
FQXSPOS4005I
FQXSPOS4006I
FQXSPOS4007I
FQXSPOS4008I
FQXSPOS4009I
FQXSPOS4010I
FQXSPPP4000I
FQXSPPP4001I
FQXSPPP4002I
FQXSPPP4003I
FQXSPPP4004I
FQXSPPP4005I
FQXSPPP4006I
FQXSPPP4007I
FQXSPPP4008I
FQXSPPP4009I
FQXSPPP4010I
FQXSPPP4011I
FQXSPPP4012I
FQXSPPP4013I
FQXSPPP4014I
FQXSPPP4015I
FQXSPPP4016I
FQXSPPP4017I
FQXSPPP4018I
FQXSPPP4019I
FQXSPPP4020I
FQXSPPP4021I
FQXSPPP4022I
FQXSPPP4023I
FQXSPPP4024I
FQXSPPP4025I
FQXSPPP4026I
FQXSPPP4027I
FQXSPPP4028I
FQXSPPP4029I
FQXSPPP4030I
FQXSPPP4031I
FQXSPPP4032I
FQXSPPP4033I
FQXSPPP4034I
FQXSPPP4035I
FQXSPPP4036I
FQXSPPP4037I
FQXSPPP4038I
FQXSPPP4039I
FQXSPPP4040I
FQXSPPP4041I
FQXSPPP4042I
FQXSPPP4043I
FQXSPPP4044I
FQXSPPP4045I
FQXSPPP4047I
FQXSPPP4048I
FQXSPPR0000I
FQXSPPR2001I
FQXSPPU0000I
FQXSPPU0001N
FQXSPPU0002G
FQXSPPU0003N
FQXSPPU2000I
FQXSPPU2001I
FQXSPPU2002I
FQXSPPU2003I
FQXSPPU2004I
FQXSPPW0001I
FQXSPPW0002L
FQXSPPW0006I
FQXSPPW0008I
FQXSPPW0009I
FQXSPPW0031J
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0055I
FQXSPPW0057J
FQXSPPW0063M
FQXSPPW0088J
FQXSPPW2001I
FQXSPPW2002I
FQXSPPW2006I
FQXSPPW2008I
FQXSPPW2031I
FQXSPPW2035I
FQXSPPW2047I
FQXSPPW2063I
FQXSPSD0000I
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0003I
FQXSPSD0005L
FQXSPSD0006L
FQXSPSD0007I
FQXSPSD2000I
FQXSPSD2001I
FQXSPSD2002I
FQXSPSD2003I
FQXSPSD2005I
FQXSPSD2006I
FQXSPSD2007I
FQXSPSE4000I
FQXSPSE4001I
FQXSPSE4002I
FQXSPSE4003I
FQXSPSE4004I
FQXSPSE4005I
FQXSPSE4007I
FQXSPSE4008I
FQXSPSE4009I
FQXSPSE4010I
FQXSPSE4011I
FQXSPSE4012I
FQXSPSE4013I
FQXSPSE4014I
FQXSPSE4015I
FQXSPSE4016I
FQXSPSE4017I
FQXSPSE4018I
FQXSPSE4019I
FQXSPSE4020I
FQXSPSE4021I
FQXSPSE4022I
FQXSPSE4023I
FQXSPSE4024I
FQXSPSE4025I
FQXSPSE4026I
FQXSPSE4027I
FQXSPSE4028I
FQXSPSE4029I
FQXSPSE4030I
FQXSPSE4031I
FQXSPSE4032I
FQXSPSE4033I
FQXSPSE4034I
FQXSPSE4035I
FQXSPSE4036I
FQXSPSE4037I
FQXSPSE4038I
FQXSPSE4039I
FQXSPSE4040I
FQXSPSE4041I
FQXSPSS4000I
FQXSPSS4001I
FQXSPSS4002I
FQXSPSS4003I
FQXSPSS4004I
FQXSPSS4005I
FQXSPSS4006I
FQXSPSS4007I
FQXSPSS4008I
FQXSPSS4009I
FQXSPTR4000I
FQXSPTR4001I
FQXSPTR4002I
FQXSPTR4003I
FQXSPUN0009G
FQXSPUN0017I
FQXSPUN0018J
FQXSPUN0019M
FQXSPUN0020N
FQXSPUN0023N
FQXSPUN0026G
FQXSPUN0026I
FQXSPUN0047N
FQXSPUN0056G
FQXSPUN0056I
FQXSPUN2012I
FQXSPUN2018I
FQXSPUN2019I
FQXSPUN2020I
FQXSPUN2023I
FQXSPUN2030I
FQXSPUP0007L
FQXSPUP4000I
FQXSPUP4001I
FQXSPUP4002I
FQXSPUP4003I
FQXSPUP4004I
FQXSPUP4005I
FQXSPWD0000I
FQXSPWD0001I
FQXSPWD0002I
FQXSPWD0003I
FQXSPWD0004I
UEFI events
UEFI events organized by severity
FQXSFDD0001G
FQXSFDD0002M
FQXSFDD0003I
FQXSFDD0004M
FQXSFDD0005M
FQXSFDD0006M
FQXSFDD0007G
FQXSFIO0005M
FQXSFIO0006M
FQXSFIO0007M
FQXSFIO0008M
FQXSFIO0009M
FQXSFIO0010M
FQXSFIO0011M
FQXSFIO0012M
FQXSFIO0013I
FQXSFIO0014J
FQXSFIO0015I
FQXSFIO0016M
FQXSFIO0017M
FQXSFIO0018I
FQXSFIO0019J
FQXSFIO0020J
FQXSFIO0021J
FQXSFIO0022J
FQXSFIO0023J
FQXSFMA0001I
FQXSFMA0001M
FQXSFMA0002I
FQXSFMA0002M
FQXSFMA0003K
FQXSFMA0004N
FQXSFMA0005N
FQXSFMA0006I
FQXSFMA0007I
FQXSFMA0008I
FQXSFMA0008M
FQXSFMA0009I
FQXSFMA0009K
FQXSFMA0010I
FQXSFMA0010K
FQXSFMA0011I
FQXSFMA0012I
FQXSFMA0012L
FQXSFMA0013I
FQXSFMA0014I
FQXSFMA0015I
FQXSFMA0016M
FQXSFMA0017I
FQXSFMA0018I
FQXSFMA0019I
FQXSFMA0022N
FQXSFMA0023M
FQXSFMA0024M
FQXSFMA0025M
FQXSFMA0026I
FQXSFMA0027K
FQXSFMA0027M
FQXSFMA0028K
FQXSFMA0028M
FQXSFMA0029I
FQXSFMA0030K
FQXSFMA0031K
FQXSFMA0032M
FQXSFMA0033M
FQXSFMA0034M
FQXSFMA0035M
FQXSFMA0036M
FQXSFMA0037G
FQXSFMA0038K
FQXSFMA0039K
FQXSFMA0040K
FQXSFMA0041K
FQXSFMA0042K
FQXSFPU0001N
FQXSFPU0002N
FQXSFPU0003K
FQXSFPU0004K
FQXSFPU0005K
FQXSFPU0006K
FQXSFPU0007K
FQXSFPU0008K
FQXSFPU0009K
FQXSFPU0010K
FQXSFPU0011K
FQXSFPU0012K
FQXSFPU0013K
FQXSFPU0014N
FQXSFPU0015K
FQXSFPU0016N
FQXSFPU0017G
FQXSFPU0018N
FQXSFPU0019N
FQXSFPU0020I
FQXSFPU0021G
FQXSFPU0021I
FQXSFPU0022G
FQXSFPU0023G
FQXSFPU0023I
FQXSFPU0024G
FQXSFPU0025I
FQXSFPU0030N
FQXSFPU0031N
FQXSFPU0032G
FQXSFPU0033G
FQXSFPU0034L
FQXSFPU4033F
FQXSFPU4034I
FQXSFPU4035M
FQXSFPU4036F
FQXSFPU4037I
FQXSFPU4038I
FQXSFPU4040M
FQXSFPU4041I
FQXSFPU4042I
FQXSFPU4043G
FQXSFPU4044I
FQXSFPU4045G
FQXSFPU4046I
FQXSFPU4047I
FQXSFPU4049I
FQXSFPU4050G
FQXSFPU4051G
FQXSFPU4052G
FQXSFPU4053G
FQXSFPU4054G
FQXSFPU4056M
FQXSFPU4080I
FQXSFPU4081I
FQXSFPU4082I
FQXSFPU4083I
FQXSFPU4084I
FQXSFPU4085I
FQXSFPW0001L
FQXSFSM0001L
FQXSFSM0002N
FQXSFSM0003N
FQXSFSM0004M
FQXSFSM0005M
FQXSFSM0006M
FQXSFSM0007I
FQXSFSM0008M
FQXSFSR0001M
FQXSFSR0002I
FQXSFSR0003G
FQXSFTR0001L
XClarity Provisioning Manager events
LXPM events organized by severity
FQXPMCL0001K
FQXPMCL0002K
FQXPMCL0003K
FQXPMCL0004K
FQXPMCL0005I
FQXPMCL0005K
FQXPMCL0006I
FQXPMCL0006K
FQXPMCL0007I
FQXPMCL0007K
FQXPMCL0008I
FQXPMCL0008K
FQXPMCL0009I
FQXPMCL0009K
FQXPMCL0010I
FQXPMCL0010K
FQXPMCL0011I
FQXPMCL0011K
FQXPMEM0001M
FQXPMEM0002I
FQXPMEM0003I
FQXPMEM0004I
FQXPMEM0005I
FQXPMEM0006M
FQXPMEM0007M
FQXPMEM0008M
FQXPMEM0009M
FQXPMNM0001G
FQXPMNM0002I
FQXPMOS0001K
FQXPMOS0002K
FQXPMOS0003K
FQXPMOS0004K
FQXPMOS0005K
FQXPMOS0006K
FQXPMOS0007K
FQXPMOS0008K
FQXPMOS0009K
FQXPMOS0010I
FQXPMOS0011I
FQXPMOS0012I
FQXPMOS0013I
FQXPMOS0014I
FQXPMOS0015I
FQXPMOS0016I
FQXPMOS0017I
FQXPMOS0018I
FQXPMOS0019I
FQXPMOS0020I
FQXPMOS0021I
FQXPMOS0022I
FQXPMOS0023I
FQXPMOS0024I
FQXPMOS0025I
FQXPMOS0026I
FQXPMOS0027I
FQXPMRS0011K
FQXPMSD0001M
FQXPMSD0002M
FQXPMSD0003M
FQXPMSD0004M
FQXPMSD0005M
FQXPMSD0006M
FQXPMSD0007M
FQXPMSD0008M
FQXPMSD0009M
FQXPMSD0010M
FQXPMSD0011M
FQXPMSR0001K
FQXPMSR0012I
FQXPMSR0021L
FQXPMSR0022I
FQXPMSR0031L
FQXPMSR0032I
FQXPMUP0001K
FQXPMUP0002K
FQXPMUP0003K
FQXPMUP0004K
FQXPMUP0005K
FQXPMUP0006K
FQXPMUP0007K
FQXPMUP0008K
FQXPMUP0101I
FQXPMUP0102I
FQXPMUP0103I
FQXPMUP0104I
FQXPMUP0105I
FQXPMUP0106I
FQXPMUP0201M
FQXPMUP0202M
FQXPMUP0203M
FQXPMUP0204M
FQXPMUP0205M
FQXPMUP0206M
FQXPMUP0207M
FQXPMUP0208M
FQXPMVD0001H
FQXPMVD0002H
FQXPMVD0003I
FQXPMVD0011K
FQXPMVD0012K
FPC events
02
03
04
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
30
31
32
33
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
E0
E1
Tech Tips
Security advisories
Getting help and technical assistance
Before you call
Collecting service data
Contacting Support
Management Tools
FPC
SMM
Introduction
Web interface access
Overview
Summary
Enclosure front overview
Enclosure rear overview
Power
Power overview
Power supply unit configuration
Power cap
Voltage Overview
Power Restore Policy
Cooling
Cooling Overview
Power supply unit Fan Speed
Acoustic Mode
System Information
Enclosure VPD
PDM VPD
SMM VPD
Power supply unit VPD
EIOM VPD
PIOR Right/Left VPD
Event Log
Configuration
Firmware Update
SMTP/SNMP/PEF
Network Configuration
Time Setting
User Account
Account Security
Services
Web Certificate
Network Time Protocol (NTP)
Backup and Restore
IPMI command
IPMI command contents
SMTP configuration parameters
LAN configuration parameters
NTP configuration parameters
ThinkSystem rack servers
ThinkSystem SR150 Type 7Y54
Resources and downloads
Server package contents
Features
Specifications
Particulate contamination
Management options
Server components
Front view
Front operator panel
Rear view
System-board layout
System-board LEDs
System-board connectors
System-board jumpers and buttons
PCIe riser assembly
Backplate
Internal cable routing
Fan cables
VGA cable
Fixed power supply cables
Backplate cables
Parts list
Server hardware setup
Server setup checklist
Installation Guidelines
System reliability guidelines
Handling static-sensitive devices
Install server hardware options
Remove the security bezel
Remove the top cover
Remove the air baffle
Install a fan
Install the simple-swap drive backplate
Install an adapter
Install the flash power module
Install the PCIe riser assembly
Install the M.2 drive
Install the CMOS battery (CR2032)
Install the fixed power supply unit
Install a DIMM
Install the processor
Install the heat sink
Install the air baffle
Install the top cover
Install a simple-swap disk drive
Install the server in a rack
Cable the server
Power on the server
Validate server setup
Power off the server
System configuration
Set the network connection for the Lenovo XClarity Controller
Firmware updates
Configuring the LAN over USB interface manually
Installing the LAN over USB Windows device driver
Configure the firmware
Memory configuration
RAID configuration
Deploy the operating system
Back up the server configuration
Update the Vital Product Data (VPD)
Update the Universal Unique Identifier (UUID)
Update the asset tag
Hardware replacement procedures
Installation Guidelines
System reliability guidelines
Working inside the server with the power on
Handling static-sensitive devices
Adapter replacement
Remove an adapter
Install an adapter
Air baffle replacement
Remove the air baffle
Install the air baffle
CMOS battery replacement
Remove the CMOS battery
Install the CMOS battery (CR2032)
DIMM replacement
Remove a DIMM
Install a DIMM
Drive replacement
Remove a simple-swap disk drive
Install a simple-swap disk drive
Drive backplate replacement
Remove the simple-swap drive backplate
Install the simple-swap drive backplate
Fan replacement
Remove a fan
Install a fan
Flash power module replacement
Remove the flash power module
Install the flash power module
Front operator panel replacement
Remove the front operator panel
Install the front operator panel
Heat sink replacement
Remove the heat sink
Install the heat sink
M.2 drive replacement
Remove the M.2 drive
Install the M.2 drive
PCIe riser assembly replacement
Remove the PCIe riser assembly
Install the PCIe riser assembly
Power supply unit replacement
Remove the fixed power supply unit
Install the fixed power supply unit
Processor replacement
Remove the processor
Install the processor
Rack latches replacement
Remove the rack latches
Install the rack latches
Security bezel replacement
Remove the security bezel
Install the security bezel
System board replacement
Remove the system board
Install the system board
Update the machine type and serial number
Enable TPM
Set the TPM policy
Assert Physical Presence
Set the TPM version
Enable UEFI Secure Boot
Top cover replacement
Remove the top cover
Install the top cover
TPM card replacement (for Chinese Mainland only)
Remove the TPM card (for Chinese Mainland only)
Install the TPM card (for Chinese Mainland only)
VGA cable replacement
Remove the VGA cable
Install the VGA cable
Complete the parts replacement
Problem determination
Event logs
Operator Panel and Error LEDs
Power supply LEDs
System-board LEDs
General problem determination procedures
Resolving suspected power problems
Resolving suspected Ethernet controller problems
Troubleshooting by symptom
Power on and power off problems
Memory problems
Hard disk drive problems
Monitor and video problems
Keyboard, mouse, or USB-device problems
Optional-device problems
Serial-device problems
Intermittent problems
Power problems
Network problems
Observable problems
Software problems
Messages
Event and alert message format
XClarity Controller events
XCC events that automatically notify Support
XCC events organized by severity
FQXSPBR4000I
FQXSPBR4001I
FQXSPBR4002I
FQXSPBR4003I
FQXSPBR4004I
FQXSPBR4005I
FQXSPBR4006I
FQXSPBR4007I
FQXSPBR4008I
FQXSPCA0002M
FQXSPCA0007J
FQXSPCA0009M
FQXSPCA0011N
FQXSPCA0017M
FQXSPCA0019N
FQXSPCA2002I
FQXSPCA2007I
FQXSPCA2009I
FQXSPCA2011I
FQXSPCA2017I
FQXSPCA2019I
FQXSPCN4000I
FQXSPCN4001I
FQXSPCN4002I
FQXSPCN4003I
FQXSPCR0001N
FQXSPCR2001I
FQXSPDA2000I
FQXSPDM4000I
FQXSPDM4001I
FQXSPDM4002I
FQXSPDM4003I
FQXSPDM4004I
FQXSPDM4005I
FQXSPDM4006I
FQXSPDM4007I
FQXSPDM4008I
FQXSPDM4009I
FQXSPEM4000I
FQXSPEM4001I
FQXSPEM4002I
FQXSPEM4003I
FQXSPEM4004I
FQXSPEM4005I
FQXSPEM4006I
FQXSPEM4007I
FQXSPEM4008I
FQXSPEM4009I
FQXSPEM4010I
FQXSPEM4011I
FQXSPEM4012I
FQXSPEM4013I
FQXSPEM4014I
FQXSPEM4015I
FQXSPEM4016I
FQXSPEM4017I
FQXSPEM4018I
FQXSPEM4019I
FQXSPEM4020I
FQXSPEM4022I
FQXSPEM4023I
&nbs