FQXSFMA0037G : Intel Optane DCPMM interleave set (DIMM [arg1]) is migrated from another system (Platform ID: [arg2]), these migrated DCPMMs are not supported nor warranted in this system.

Intel Optane DCPMM interleave set (DIMM [arg1]) is migrated from another system (Platform ID: [arg2]), these migrated DCPMMs are not supported nor warranted in this system.

Severity

Error

User Response

Complete the following steps:
  1. (Service technician only) Remove the DCPMMs and install them back to the original system.
  2. Delete all the filesystems and namespaces in the operating system.
  3. If the DCPMMs are secured with passphrase, disable security.
  4. Perform secure erase on all the DCPMMs, and reboot the system.
  5. Set all the DCPMMs as not interleaved, and reboot the system.
  6. Refer to system publication of target system for a supported DCPMM configuration. Then, remove the DCPMMs and install them to the target system based on this configuration.
  7. Power on the system, and configure the DCPMMs.
  8. If the problem remains, contact Lenovo Support.