FQXSPPW0077N : Sensor [SensorElementName] has transitioned to non-recoverable.

Sensor [SensorElementName] has transitioned to non-recoverable.

This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

Severity

Error

Alert Category

Critical - Power

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0530

SNMP Trap ID

4

Automatically Notify Support

No

User Response

If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is solved: Use the Lenovo Power Configurator utility to determine current system power consumption. For more information and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html. Follow actions in "Power Problems and Solving Power Problems". If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved: Check power supply n LED. Remove the failing power supply. (Trained technician only) Replace the system board. (n = power supply number) If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved: Check power supply n LED. Remove the failing power supply. Follow actions in "Power Problems and Solving Power Problems". (Trained technician only) Replace the system board. (n = power supply number) If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved: Check power supply n LED. Replace power supply n. (n = power supply number)