FQXSPUN0018J : Sensor [SensorElementName] has transitioned from normal to non-critical state.

Sensor [SensorElementName] has transitioned from normal to non-critical state.

This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

Severity

Warning

Alert Category

Warning - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0520

SNMP Trap ID

60

Automatically Notify Support

No

User Response

if sensor is GPT Status 1. Check the Lenovo support site for service bulletins or firmware updates that apply to this GPT error. 2. Set the UEFI setting DISK GPT Recovery to Automatic. 3. Replace the corrupt disk. if sensor is TPM Lock or TPM Phy Pres Set 1. Update the server firmware (see Recovering the server firmware). 2. If the problem persists, (trained technician only) replace the system board (see Removing the system board and Installing the system board). if sensor is RAID Vol State 1. Run the hard disk drive diagnostic test on drive n. 2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)