Configuration

Configuration tabs settings are used to manage SMM2 module.

Figure 1. Configuration
Configuration
There are eight sections:
  • Firmware Update

  • SMTP

  • SNMP

  • PEF

  • Network Configuration

  • Time Setting

  • User Account

  • Account Security

  • Web Certificate

Note: By pressing hardware reset button for more than 4 seconds, all settings (except Time Setting) can be restored to out-of-factory default settings.

All settings, except time setting, in the configuration tab can be restored to out-of-factory default settings through coin battery removal or by pressing hardware reset button for more than 4s.

Complete the following steps to remove the coin battery:
  1. Pull SMM2 module out of the chassis.

  2. Remove coin battery from SMM2 module.

  3. Insert SMM2 module without battery back to chassis, boot up, and wait for SMM2 to reboot.

  4. The following sings can be observed during SMM2 boot up and reboot.

    1. Power LED lit on.

    2. Heartbeat LED blinks for 0.3 seconds on and 3.8 seconds off.

    3. Checklog LED lit on due to lack of battery

    4. SMM2 then reboot and have fan spin up, Power LED lit, Heartbeat LED blinks and Checklog LED on again.

  5. After observing Checklog LED lit up again after SMM2 reboot, pull SMM2 module out of the chassis.

  6. Install the battery back to SMM2 module.

  7. Insert SMM2 module with battery back to chassis.