FQXSFMA0025M : NVDIMM Supercap has been disconnected. NVDIMM will lose its backup ability until this is corrected. [arg1]

NVDIMM Supercap has been disconnected. NVDIMM will lose its backup ability until this is corrected. [arg1]

Severity

Error

User Response

Complete the following steps:
  1. If the server has recently been installed, moved, serviced, or upgraded, verify that the DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel.
  2. If no problem is observed on the DIMM connectors or the problem persists, Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error
  3. If the problem persists, replace the DIMM identified by LightPath and/or event log entry.
  4. If problem recurs on the same DIMM connector, inspect DIMM connector for foreign material and remove, if found.
  5. If problem persists, collect Service Data log.
  6. Contact Lenovo Support.