Sensor [SensorElementName] has transitioned to critical from a less severe state.
This message is for the use case when an implementation has detected a
Sensor transitioned to critical from less severe.
Alert Category
Critical - Voltage
CIM Information
Prefix:PLAT
and ID:0522
Automatically Notify Support
No
User Response
Complete the following steps:
- Reseat the faulty node in D2 enclosure (AC cycle).
- Check if multiple nodes within the D2 enclosure are reporting SysBrd Vol fault:
- If the fault is reported by single node swap the failing node with a good node.
- If fault follows the node please replace the system board in the compute node (trained technician only).
- If the fault follows the slot within the D2 enclosure please replace the shuttle (trained technician only).
- If multi-node failure in a chassis, AC cycle entire chassis by disconnect power cords and plugging them back into system again.
- If problem persists, do steps 2.