Shock and vibration specifications

The following information is a summary of the shock and vibration specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

SE350 system configuration Vibration (when server is in operation) Shock (when server is in operation) Environmental vibration criteria
Left wing Right wing

IEC Stationary 0.15Grms, 30mins15G, 11ms

3.06 Grms, 15mins 30G, 11ms

3.06 Grms, 60mins 30G, 11ms

Four M.2 SATA drives None 3.06Grms, 3-500 Hz, 60 min/axis 30G, 11ms, half-sine, ±X, ±Y, ±Z
Four M.2 SATA drives NVIDIA T4 GPU 3.06Grms, 3-500 Hz, 15 min/axis 30G, 11ms, half-sine, ±X, ±Y, ±Z  
Four M.2 NVMe drives (with heatsink) Four M.2 NVMe drives (with heatsink) 0.21Grms, 5-500 Hz, 15 min/axis 15G, 3ms, half-sine, ±X, ±Y, ±Z    
Four M.2 NVMe drives (with heatsink) NVIDIA T4 GPU 0.21Grms, 5-500 Hz, 15 min/axis 15G, 3ms, half-sine, ±X, ±Y, ±Z