Table 1. Limited maximal number of SN550 V2 in the same chassis
2500 W power output (200-208 V ac)
Processor TDP
  • N+1
  • N=4
  • 5 PSUs
  • With throttle
  • N+1
  • N=3
  • 4 PSUs
  • With throttle
  • N+N
  • N=3
  • 6 PSUs
  • With throttle
  • N+1
  • N=5
  • 6 PSUs
  • No throttle
  • N+N
  • N=3
  • 6 PSUs
  • No throttle
105 W 14 14 14 14 9
120 W 14 13 14 14 8
135 W 14 12 13 13 8
140 W 14 12 13 13 8
150 W 14 12 12 12 7
165 W 14 11 11 12 7
185 W 13 10 10 11 6
195 W 13 9 9 10 6
205 W 13 9 9 10 6
230W 12 9 9 9 5
2745 W power output (220-240 V ac)
Processor TDP
  • N+1
  • N=4
  • 5 PSUs
  • With throttle
  • N+1
  • N=3
  • 4 PSUs
  • With throttle
  • N+N
  • N=3
  • 6 PSUs
  • With throttle
  • N+1
  • N=5
  • 6 PSUs
  • No throttle
  • N+N
  • N=3
  • 6 PSUs
  • No throttle
105 W 14 14 14 14 10
120 W 14 13 14 14 9
135 W 14 12 13 14 9
140 W 14 12 13 14 9
150 W 14 12 12 13 8
165 W 14 11 11 13 8
185 W 14 11 11 12 7
195 W 14 10 10 11 6
205 W 14 10 10 11 6
230W 13 9 9 10 6