Show AutoSupport configuration

The show storageArray autoSupport command displays the AutoSupport bundle collection settings for the storage array.

Supported Arrays

This command is operational for either the DE2000H, DE4000H, DE4000F, DE6000H, or DE6000F storage arrays.

Roles

To execute this command on an storage array, you must have the Storage Admin or Support Admin or Storage Monitor role.

Context

The command output from this command shows the following configuration information:

Syntax

show storageArray autoSupport

Parameters

None.

Examples


   SMcli -n Array1 -c "show storageArray autoSupport;"

   The AutoSupport feature is enabled on this storage array.
   The AutoSupport OnDemand feature is enabled on this storage array.
   The AutoSupport Remote Diagnostics feature is enabled on this storage array.

   Delivery Method: Email (SMTP)
     Destination email address: http://support.mycompany.com/put/AsupPut/
     Mail relay server: ra.eng.lenovo.com
     Sender email address: user@lenovo.com
   -or-
   Delivery Method: HTTP
     Destination IP address: http://support.mycompany.com/put/AsupPut/
     Connection: Direct
         -or-
     Connection: Proxy server
      Host Address: 10.227.76.178
       Port number: 8080
       Authentication required: Yes
        User name: admin
        Password: ********
         -or-
     Connection: Automatic proxy configuration script (PAC)
      Script location: http://esgweb.eng.mycompany.com/proxy.pac

   The AutoSupport daily schedule preferred time range is from 12:00 AM to 01:00 AM.
   The AutoSupport weekly schedule preferred time range is from 10:00 PM to 11:00 PM on Thursday, Saturday.

   AutoSupport Capable  AutoSupport OnDemand Capable  Chassis Serial Number  Daily Schedule  Weekly Schedule
   Yes (enabled)        Yes                           SX94500434             12:55 AM        10:08 PM on Thursdays

   SMcli completed successfully.