The show syncMirror synchronizationProgress command returns the progress of data synchronization between the primary volume and the secondary volume in a Synchronous Mirroring configuration.
This command applies to an individual DE2000H, DE4000H, DE4000F, DE6000H, or DE6000F storage array.
To execute this command on an storage array, you must have the Storage Admin or Storage Monitor role.
This command shows the progress as a percentage of data synchronization that has been completed.
show syncMirror (localVolume [volumeName] |
localVolumes [volumeName1... volumeNameN]) synchronizationProgress
Parameter | Description |
---|---|
volume | The name of the primary volume of the remote mirrored pair for which you want to check synchronization progress. Enclose the volume name in square brackets ([ ]). If the volume name has special characters or numbers, you must enclose the volume name in double quotation marks (" ") inside square brackets. |
volumes | The names of the primary volume of the remote mirrored pair for which you want to check synchronization progress. Enter the names of the volumes using these rules:
If the volume names have special characters or consist only of numbers, enter the names using these rules:
|