The reset controller command resets a controller, and is disruptive to I/O operations.
This command applies to an individual DE2000H, DE4000H, DE4000F, DE6000H, or DE6000F storage array.
To execute this command on an storage array, you must have the Storage Admin role.
reset controller [(a|b)]
Parameter | Description |
---|---|
controller | The controller that you want to reset. Valid controller identifiers are a or b , where a is the controller in slot A , and b is the controller in slot B . Enclose the controller identifier in square brackets ([ ]). If you do not specify a controller, the storage management software returns a syntax error. |
The controller that receives the reset controller command resets the controller specified. For example, if the reset controller command is sent to controller A to request a reset of controller A , then controller A reboots itself by doing a soft reboot. If the reset controller command is sent to controller A to request a reset of controller B , then controller A holds controller B in reset and then releases controller B from reset, which is a hard reboot. A soft reboot in some products only resets the IOC chip. A hard reboot resets both the IOC and the expander chips in the controller.