If you removed a HIC from the original controller canister,
you must install that HIC in the new controller canister.
Before
you begin
- You must have a replacement
controller canister with the same part number as the controller canister
you are replacing.
- You must have a #1 Phillips
screwdriver.
- You have an ESD wristband, or you have
taken other antistatic precautions.
- Using a #1 Phillips
screwdriver, remove the four screws that attach the blank faceplate
to the replacement controller canister, and remove the faceplate.
- Align the three
thumbscrews on the HIC with the corresponding holes on the controller,
and align the connector on the bottom of the HIC with the HIC interface
connector on the controller card.
Be careful not to scratch or bump the components on the bottom
of the HIC or on the top of the controller card.
- Carefully lower
the HIC into place, and seat the HIC connector by pressing gently
on the HIC.
- Hand-tighten
the HIC thumbscrews.
Do not use a screwdriver, or you might over tighten the screws.
-
Using a #1 Phillips screwdriver, attach the HIC faceplate you
removed from the original controller canister to the new controller
canister with four screws.