For SLES 12, I/O is directed to virtual device targets by the Linux host. DM-MP manages the physical paths underlying these virtual targets.
Make sure you are running I/O only to the virtual devices created by DM-MP and not to the physical device paths. If you are running I/O to the physical paths, DM-MP cannot manage a failover event and the I/O fails.
You can access these block devices
through the dm
device or the symlink
in /dev/mapper
, for example:
/dev/dm-1
/dev/mapper/eui.00001bc7593b7f5f00a0980000af4462
The
following example output from the nvme list
command
shows the host node name and its correlation with the namespace ID.
NODE SN MODEL NAMESPACE
/dev/nvme1n1 021648023072 NetApp E-Series 10
/dev/nvme1n2 021648023072 NetApp E-Series 11
/dev/nvme1n3 021648023072 NetApp E-Series 12
/dev/nvme1n4 021648023072 NetApp E-Series 13
/dev/nvme2n1 021648023151 NetApp E-Series 10
/dev/nvme2n2 021648023151 NetApp E-Series 11
/dev/nvme2n3 021648023151 NetApp E-Series 12
/dev/nvme2n4 021648023151 NetApp E-Series 13
Column | Description |
---|---|
|
The node name includes two parts:
|
|
The Namespace column lists the namespace ID (NSID), which is the identifier from the storage array perspective. |
In the following multipath -ll
output,
the optimized paths are shown with a prio
value
of 50, while the non-optimized paths are shown with a prio
value of 10.
The Linux operating system routes I/O to the
path group that is shown as status=active
, while
the path groups listed as status=enabled
are available
for failover.
eui.00001bc7593b7f500a0980000af4462 dm-0 NVME,NetApp E-Series
size=15G features='1 queue_if_no_path' hwhandler='0' wp=rw
|-+- policy='service-time 0' prio=50 status=active
| `- #:#:#:# nvme1n1 259:5 active ready running
`-+- policy='service-time 0' prio=10 status=enabled
`- #:#:#:# nvme2n1 259:9 active ready running
eui.00001bc7593b7f5f00a0980000af4462 dm-0 NVME,NetApp E-Series
size=15G features='1 queue_if_no_path' hwhandler='0' wp=rw
|-+- policy='service-time 0' prio=0 status=enabled
| `- #:#:#:# nvme1n1 259:5 failed faulty running
`-+- policy='service-time 0' prio=10 status=active
`- #:#:#:# nvme2n1 259:9 active ready running
Line item | Description |
---|---|
|
This line and the following line show that This namespace is owned by controller A. |
|
This line shows the failover path for namespace
10, with a This namespace is owned by controller B. |
|
This example shows |
|
Note that the |