You verify Internet Protocol (IP) network connections by using ping tests to ensure the host and array are able to communicate.
ping -I <hostIP> <targetIP>
packet size
bit. The -d switch sets the debug option. These options allow jumbo frames
of 9,000 bytes to be successfully transmitted between the iSCSI initiator
and the target. ping -I <hostIP> -s 8972 -d <targetIP>
192.0.2.8
.#ping -I 192.0.2.100 -s 8972 -d 192.0.2.8
Pinging 192.0.2.8 with 8972 bytes of data:
Reply from 192.0.2.8: bytes=8972 time=2ms TTL=64
Reply from 192.0.2.8: bytes=8972 time=2ms TTL=64
Reply from 192.0.2.8: bytes=8972 time=2ms TTL=64
Reply from 192.0.2.8: bytes=8972 time=2ms TTL=64
Ping statistics for 192.0.2.8:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 2ms, Maximum = 2ms, Average = 2ms
Packet needs to be fragmented
but DF set
), verify the MTU size (jumbo frame support) for
the Ethernet interfaces on the host server, storage controller, and
switch ports.