You can set or change the shelf ID for a controller shelf
or a drive shelf by using the ODP push button.
Before you begin
Each controller shelf or
drive shelf has LEDs located on the operator display panel (ODP).
You might need to remove the left end cap to see the ODP push button.
The controller shelf or drive shelf must be powered on before you
begin this task.
The following figure shows the ODP push button on controller
shelf and drive shelf with 12 drives.
Figure 1. ODP push button on controller shelf and drive shelf with 12
drives
The following figure shows the ODP push button on controller
shelf and drive shelf with 24 drives.
Figure 2. ODP push button on controller shelf and drive shelf with 24
drives
The following figure shows the ODP push button on controller
shelf and drive shelf with 60 drives.
Figure 3. ODP push button on controller shelf and drive shelf with 60
drives
- Press and hold the push button until the first number on
the seven-segment display starts to blink.
It might take up to three seconds for the number to blink. If
the number does not blink in this time, release the button and press
it again. Make sure to press the button all the way in.
- Change the first number of the shelf ID by repeatedly pressing
the push button to advance the number until you reach the desired
number from 0 to 9.
The first number continues to blink.
- Press and hold the button until the second number on the
digital display starts to blink.
It might take up to three seconds for the second number to blink.
The first number on the seven-segment display stops blinking.
- Change the second number of the shelf ID by repeatedly
pressing the button to advance the number until you reach the desired
number from 0 to 9.
The second number continues to blink.
- Lock in the desired number, and exit the programming mode
by pressing and holding the button until the second number stops blinking.
It might take up to three seconds for the second number to stop
blinking.